EasyManua.ls Logo

Pentair MASTERTEMP 125 - Operating; To Turn off Gas to Appliance

Pentair MASTERTEMP 125
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Rev. B 8/14 MASTERTEMP
®
125 Pool and Spa Heater Installation and User’s Guide
33
Section 4. Operation Instructions
OPERATING INSTRUCTIONS
 67235HDGWKHVDIHW\LQIRUPDWLRQRQSDJH
 6HWERWKSRRODQGVSDWKHUPRVWDWVWRWKHORZHVWVHWWLQJV
 7XUQRIIDOOHOHFWULFSRZHUWRWKHDSSOLDQFH7XUQ2))WKH0DQXDO
6KXW2II9DOYHDVVKRZQEHORZ
 7KLVDSSOLDQFHGRHVQRWKDYHDSLORW,WLVHTXLSSHGZLWKDQLJQLWLRQ
GHYLFHZKLFKDXWRPDWLFDOO\OLJKWVWKHEXUQHU'RQRWWU\WROLJKWWKH
EXUQHUE\KDQG
 5HPRYHWKHDFFHVVGRRUSDQHOVE\XQIDVWHQLQJWKHWZRVFUHZV
ORFDWHGRQHDFKGRRUWKHQOLIWXSDQGRXWIURPWKHERWWRPRIWKHSDQHO
WRUHPRYH,IQHFHVVDU\WKHVFUHZVPD\EHXVHGDVKDQGOHV
VHH
)LJXUH
 7RJJOH6W\OH9DOYH3XOOWRJJOHWRZDUG\RXWRWXUQJDVRII
VHH
)LJXUH
 :DLW¿YHPLQXWHVWRFOHDURXWDQ\JDV,I\RXWKHQVPHOOJDV
6723)ROORZ³%´LQWKH³%HIRUH6WDUWXS´LQVWUXFWLRQVSDJH
,I\RXGRQ¶WVPHOOJDVJRWRWKHQH[WVWHS
 7XUQ21WKH0DQXDO6KXW2II9DOYHDVVKRZQEHORZ7RJJOH6W\OH
9DOYH3XVKWKHWRJJOHVZLWFKDZD\IURP\RXWRVZLWFKWKHJDVRQ
 5HSODFHWKH'RRU$FFHVV3DQHOV$OOSDQHOVPXVWEHLQSODFHZKHQ
RSHUDWLQJWKHKHDWHU
 6HWZD\YDOYHVRQLQOHWDQGRXWOHWWRSRRORUVSDDVDSSURSULDWH
 7XUQRQDOOHOHFWULFSRZHUWRWKHDSSOLDQFH
 3UHVVHLWKHUWKH322/21RU63$21EXWWRQVZLWFKRQWKHRSHUDWLQJ
FRQWURO
 6HWWKHWKHUPRVWDWWRGHVLUHGVHWWLQJNOTICE:6HWSRLQWPXVWEHDERYH
DFWXDOZDWHUWHPSHUDWXUHRUEXUQHUZLOOQRW¿UH6HH³23(5$7,1*WKH
&21752/3$1(/´
 7KHEORZHUVKRXOGFRPHRQLPPHGLDWHO\DQGDIWHUDERXWVHFRQGVWKH
EXUQHUVKRXOG¿UH:KHQRSHUDWLQJIRUWKH¿UVWWLPHWKHEXUQHUPD\QRW
¿UHRQWKH¿UVWWU\EHFDXVHRIDLULQWKHJDVOLQH,ILWGRHVQRW¿UHDW¿UVW
SXVKWKH2))VZLWFKZDLW¿YHPLQXWHVDQGDJDLQSXVKWKH322/RU
63$21VZLWFK7KHEXUQHUVKRXOG¿UHDIWHUDERXWVHFRQGV<RX
PD\KDYHWRUHSHDWWKLVXQWLODOORIWKHDLUKDVFOHDUHGWKHJDVOLQH
 7KHEXUQHUVKRXOG¿UHXQWLOWKHSRROVSDWHPSHUDWXUHUHDFKHVWKHGHVLUHG
WHPSHUDWXUHVHWRQWKHWKHUPRVWDW7KHEORZHUZLOOFRQWLQXHWRUXQIRUDERXWVHFRQGVDIWHUWKHEXUQHUVKXWV
RII,IDQ\RIWKHVDIHW\LQWHUORFNVVKRXOGRSHQGXULQJEXUQHURSHUDWLRQWKHEXUQHUVKXWVRIILPPHGLDWHO\EXWWKH
EORZHUFRQWLQXHVWRUXQIRUDERXWVHFRQGV6KRXOGRYHUKHDWLQJRFFXURUWKHJDVVXSSO\IDLOWRVKXWRIIWXUQRII
WKHPDQXDOJDVFRQWUROYDOYHWRWKHDSSOLDQFH
 ,IWKHDSSOLDQFHZLOOQRWRSHUDWHIROORZWKHLQVWUXFWLRQVEHORZ
³7278512))*$6727+($33/,$1&(´DQGFDOO\RXUVHUYLFH
WHFKQLFLDQRUJDVVXSSOLHU
Figure 27.
Water
Pressure
Switch
Figure 26.
Gas control is shown OFF.
Push toggle switch away
from you to switch ON.
Manual
Shut-off
Valve
TO TURN OFF GAS TO APPLIANCE
 3UHVVWKH2))EXWWRQRQRSHUDWLQJFRQWURO
 6ZLWFKRIIDOOHOHFWULFSRZHUWRWKHXQLW
7XUQ2))WKH0DQXDO6KXW2II9DOYHDVVKRZQRQULJKW
 5HPRYHWKHDFFHVVGRRUSDQHOVVHH
)LJXUH
 7RJJOH6W\OH9DOYH3XOOWRJJOHWRZDUG\RXWRWXUQJDVRIIVHH)LJXUH
 5HSODFHWKH$FFHVV'RRU3DQHOV
MANUAL SHUT-OFF VALVE LOCATION