Rev. B 8/14 MASTERTEMP
®
125 Pool and Spa Heater Installation and User’s Guide
25
1' Min.
4' Min.4' Min.
4' Min.
4' Min.
3' Minimum clearance if
horizontal distance to
exhaust opening is less
than 10 feet.
Forced Air
Inlet
Vent
Terminatio
n
1' Minimum
above snow or
finished grade
(whichever is
higher)
At least 7'
above grade
adjacent
to public
walkways
Vent
Termination
Vent
Terminatio
n
Gas Meter
Max. 12"
Min. 3"
Figure 17.
 9HQW7HUPLQDWLRQ±+RUL]RQWDO
7KHWHUPLQDOPXVWEHORFDWHG86±6HH
)LJXUH
 DWOHDVW´DQGDWPRVW´RXWIURPWKHZDOOVHH)LJXUHIROORZLQJWKHYHQWPDQXIDFWXUHU¶VLQVWUXFWLRQV
 DWOHDVW´DERYH¿QLVKHGJUDGHRUWKHQRUPDOO\H[SHFWHGVQRZDFFXPXODWLRQOHYHOZKLFKHYHULVKLJKHU
 DWOHDVWIHHWEHORZRUKRUL]RQWDOO\IURPRUIRRWDERYHDQ\GRRUVRUZLQGRZVRUJUDYLW\DLULQOHWWRDEXLOGLQJ
 DWOHDVWIHHWDERYHDQ\IRUFHGDLULQOHWORFDWHGZLWKLQIHHW
 DWOHDVWIHHWKRUL]RQWDOO\IURPHOHFWULFPHWHUVJDVPHWHUVUHJXODWRUVDQGUHOLHIHTXLSPHQW
 DWOHDVWIHHWDERYHJUDGHDGMDFHQWWRZDONZD\VRUVLPLODUWUDI¿FDUHDV
7KHWHUPLQDOPXVWEHORFDWHG&DQDGD±6HH
)LJXUH
 DWOHDVWIHHW0IURPDQ\RSHQLQJLQWRDEXLOGLQJ
 DWOHDVW´0DERYH¿QLVKHGJUDGHRUWKHQRUPDOO\H[SHFWHGVQRZDFFXPXODWLRQOHYHOZKLFKHYHULVKLJKHU
 DWOHDVWIHHW0KRUL]RQWDOO\IURPHOHFWULFPHWHUVJDVPHWHUVUHJXODWRUVDQGUHOLHIHTXLSPHQW
 DWOHDVWIHHW0DERYHJUDGHDGMDFHQWWRZDONZD\VRUVLPLODUWUDI¿FDUHDV
$OORZ DW OHDVW WKUHH IHHW 0 YHUWLFDO FOHDUDQFH
RYHU YHQW WHUPLQDWLRQ ZKHQ WHUPLQDWLQJ XQGHU DQ
RYHUKDQJ
$YRLGFRUQHUVRUDOFRYHVZKHUHVQRZRUZLQGFRXOG
KDYH DQ HIIHFW ([KDXVW PD\ DIIHFW VKUXEEHU\ DQG
VRPHEXLOGLQJPDWHULDOV.HHSVKUXEEHU\DZD\IURP
WHUPLQDWLRQ7R SUHYHQW VWDLQLQJ RU GHWHULRUDWLRQ
VHDOLQJ RU VKLHOGLQJ H[SRVHG VXUIDFHV PD\ EH
UHTXLUHG
WARNING
Fire Hazard. Do not run the heater vent into a common
vent with any other appliance. Do not run the Special
Gas Vent into, through, or within any active vent such
3" (7.6 cm) Min.,
12" (30.5 cm) M
a
Clearanc
e
Condensate
drain w/Trap
Condensate
Tee
Support
weight
of pipe
Listed
Terminal
Metal Special
Gas Vent
requires
Appliance
Adapter
Metal
Vent
Body
Slope at least
1/4" per foot
(2 cm per Meter)
down towards
condensate drain
(Optional)
Figure 18.
Section 3. Installation Instructions

Table of Contents

Other manuals for Pentair MASTERTEMP 125

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pentair MASTERTEMP 125 and is the answer not in the manual?

Pentair MASTERTEMP 125 Specifications

General IconGeneral
BTU Output125, 000 BTU/hr
Fuel TypeNatural Gas or Propane
Ignition SystemElectronic
Minimum Flow Rate20 GPM
Maximum Working Pressure50 PSI
Efficiency82%
Water Connections1.5 inch
CertificationsANSI Z21.56
Voltage120V