MicroBrite Color and White Light Installation and User’s Guide
14
1.
EasyTouch or IntelliTouch Control System Load Center:
Unlatch the
enclosure door spring latch, and open the door.
2.
Discharge Electrostatic energy before removing the cover by rst
touching the metal part of the enclosure.
3. Loosen the two (2) retaining screws from the HIGH VOLTAGE FRONT PANEL.
Remove the panel from the enclosure.
4. Run the MicroBrite light power cord to the transformer which is attached to
the auxiliary relay in the EasyTouch/IntelliTouch Control System load center.
5. Connect the 120 VAC side of a 12 VAC transformer to the LOAD SIDE of one
of the auxiliary (AUX) relays in the load center.
6. Connect the Neutral conductor from the 12 VAC transformer to the Neutral
bus bar in the load center.
7. After the connection has been completed, close the control panel and secure
it with the two (2) retaining screws.
8. Close the load center front door. Fasten the spring latch.
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION
Always disconnect AC power to EasyTouch and IntelliTouch Control System load
center at the circuit breaker before servicing, or removing the
HIGH VOLTAGE
FRONT PANEL
. Failure to do so could result in death or serious injury to installer,
service person, pool users, or others due to electrical shock.