PERFORMANCE DATA
Important Notice: Read this performance data and compare
the capabilities of these systems with your actual water
treatment needs. It is recommended that, before installing a
water treatment system, you have your water supply tested to
determine your actual water treatment needs.
This system has been tested according to NSF/ANSI 42 and
53 for the reduction of the substances listed below. The
concentration of the indicated substances in water entering
the system was reduced to a concentration less than or
equal to the permissible limit for water leaving the system as
specified in NSF/ANSI 42 and 53.
WARNING:
Do not use with water that is microbiologically
unsafe or of unknown quality without adequate
disinfection before or after the system.
QC10CBR WITH QC10CBRR CARTRIDGE
Substance
Influent Challenge
Concentration
Max. Permissible Product
Water Concentration
Reduction
Requirements
Minimum
Reduction
Average
Reduction
Standard 42—Aesthetic Effects
Chlorine 2.0 mg/L ± 10% ≥ 50% 97.5%
Particulate,
Class I
Particles*
0.5 - 1 µm
at least
10,000
particles/mL
≥ 85% 99.7%
Standard 53—Health Effects
Cyst** Minimum 50,000/L 99.95% 99.99%
Turbidity 11 mg/L ± 1 NTU 0.5 NTU 99.1%
Lead (pH
6.5)
0.15 mg/L ± 10% 0.010 mg/L 99.3%
Lead (pH
8.5)
0.15 mg/L ± 10% 0.010 mg/L 97.9%
Atrazine 0.009 mg/L ± 10% 0.003 mg/L 92.0%
Lindane 0.002 mg/L ± 10% 0.0002 mg/L 99.1%
Flow Rate = 0.5 gpm (1.9 L/min)
Capacity = 500 gallons (1,890 L) or 6 months
* Reduces particles as small as 0.5-1 micron in size by mechanical means.
**NSF/ANSI Standard 53 certified to reduce cysts such as Cryptosporidium and Giardia by
mechanical means.
QC10GAC WITH QC10GACR CARTRIDGE
Substance
Influent Challenge
Concentration
Max. Permissible Product
Water Concentration
Reduction
Requirements
Minimum
Reduction
Average
Reduction
Standard 42—Aesthetic Effects
Chlorine 2.0 mg/L ± 10% ≥ 50% 84.2%
Flow Rate = 0.75 gpm (2.8 L/min)
Capacity = 2,500 gallons (9,460 L) or 9 months
QC10EP WITH QC10EPR CARTRIDGE
Substance
Influent Challenge
Concentration
Max. Permissible Product
Water Concentration
Reduction
Requirements
Minimum
Reduction
Average
Reduction
Standard 42—Aesthetic Effects
Chlorine 2.0 mg/L ± 10% ≥ 50% 93.5%
Flow Rate = 0.5 gpm (1.9L/min)
Capacity = 1,500 gallons (5,670 L) or 9 months
Testing was performed under standard laboratory conditions; actual performance may vary.
QC10TSGAC WITH QC10TSGACR
CARTRIDGE
Substance
Influent Challenge
Concentration
Max. Permissible Product
Water Concentration
Reduction
Requirements
Minimum
Reduction
Average
Reduction
Standard 42—Aesthetic Effects
Chlorine 2.0 mg/L ± 10% ≥ 50% 89.5% 96.5%
Flow Rate = 0.75 gpm (2.8 L/min)
Capacity = 1,700 gallons (6,435 L) or 9 months
Testing was performed under standard laboratory conditions; actual performance may vary.
Test Conditions:
Flow Rate = 0.5 gpm (QC10-CBR & QC10-EP)
= 0.75 gpm (QC-GAC, QC10-TSGAC)
Inlet Pressure = 60 psi (4.1 bar)
pH = 7.5 ± 1
Temperature = 68˚F ± 5˚F (20˚C ± 2.5˚C)
Operating Requirements:
Pressure = 30-125 psi (2.1-8.62 bar)
Temperature = 40˚-100˚F (4.4˚-37.8˚C)
Turbidity = 5 NTU Max
California Residents - Proposition 65
WARNING:
This product contains chemicals known to the
State of California to cause cancer or birth
defects or other reproductive harm.
EPA Est. #090375-MEX-001 PENTEK
®