Hold Time
Wait time in seconds for a keepalive message from a Neighbor before considering
the BGP connection as stalled.
The value must be either 0 (infinite hold time) or between 3 and 65535 inclusively.
Default: 240
Next Hop Self
Enable this option to advertise your own source address as the next hop when
propagating routes.
iBGP Local
Preference
This is the metric advertised to iBGP Neighbors to indicate the preference for
external routes. The value must be between 0 to 4294967295 inclusively.
Default: 100
BFD
Enable this option to add Bidirectional Forwarding Detection for path failure. All
directly connected Neighbors that use the same physical interface share the same
BFD settings. All mulithop Neighbors share the same multihop BFD settings. You
can configure BFD settings in the BGP profile listing page after this option is
enabled.
Network
Advertising
Select the Networks that will be advertised to the BGP Neighbor.
Static Route
Advertising
Enable this option to advertise static LAN routes. Static routes that match the
Excluded Networks table will not be advertised.
Custom Route
Advertising
Additional routes to be advertised to the BGP Neighbor.
Advertise OSPF
Route
When this box is checked, every learnt OSPF route will be advertised.
Set Community
Assign a prefix to a Community.
Community:
https://www.peplink.com
212
Copyright @ 2021 Peplink

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the peplink Pepwave MAX BR1 MK2 and is the answer not in the manual?

peplink Pepwave MAX BR1 MK2 Specifications

General IconGeneral
Brandpeplink
ModelPepwave MAX BR1 MK2
CategoryWireless Router
LanguageEnglish

Related product manuals