give your AP further instructions.
Max number of
Clients
A
This field determines the maximum clients that can be connected to APs under this
profile.
Client Signal
Strength
Threshold
A
This field determines that maximum signal strength each individual client will receive.
The measurment unit is megawatts.
Beacon Rate
A
This drop-down menu provides the option to send beacons in different transmit bit rates.
The bit rates are 1Mbps, 2Mbps, 5.5Mbps, 6Mbps, and 11Mbps.
Beacon Interval
A
This drop-down menu provides the option to set the time between each beacon send.
Available options are 100ms, 250ms, and 500ms.
DTIM
A
This field provides the option to set the frequency for beacon to include delivery traffic
indication messages (DTIM). The interval unit is measured in milliseconds.
RTS Threshold
A
This field provides the option to set the minimum packet size for the unit to send an RTS
using the RTS/CTS handshake. Setting 0 disables this feature.
Fragmentation
Threshold
A
Determines the maximum size (in bytes) that each packet fragment will be broken down
into. Set 0 to disable fragmentation.
Distance/Time
Converter
A
Select the distance you want your Wi-Fi to cover in order to adjust the below parameters.
Default values are recommended.
Slot Time
A
This field provides the option to modify the unit wait time before it transmits. The default
value is 9μs.
ACK Timeout
A
This field provides the option to set the wait time to receive acknowledgement packet
before doing retransmission. The default value is 48μs.
Frame
Aggregation
A
With this feature enabled, throughput will be increased by sending two or more data
frames in a single transmission.
Frame Length
This field is only available when Frame Aggregation is enabled. It specifies the frame
length for frame aggregation. By default, it is set to 50000.
A
- Advanced feature. Click the button on the top right-hand corner to activate.
Web Administration Settings

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pepwave MAX BR1 Mini and is the answer not in the manual?

Pepwave MAX BR1 Mini Specifications

General IconGeneral
BrandPepwave
ModelMAX BR1 Mini
CategoryWireless Router
LanguageEnglish

Related product manuals