Check for ease of resetting. The service indicator
should reset in less than three pushes.
Check the movement of the yellow core when the
engine is accelerated to the engine rated speed.
The yellow core should latch approximately at the
greatest vacuum that is attained.
If the service indicator does not reset easily, or if the
yellow core does not latch at the greatest vacuum,
the service indicator should be replaced. If the new
service indicator will not reset, the hole for the service
indicator may be restricted.
The service indicator may need to be replaced
frequently in environments that are severely dusty.
i01941505
Engine Ground - Inspect/Clean
Inspect the wiring harness for good connections.
Perkins use the starter motor in order to ground the
engine. Check the connection on the starter motor at
every oil change. Ground wires and straps should be
combined at engine grounds. All grounds should be
tight and free of corrosion.
Clean the grounding stud on the starter motor and
the terminals with a clean cloth.
If the connections are corroded, clean the
connections with a solution of baking soda and
water.
Keep the grounding stud and the strap clean and
coated with suitable grease or petroleum jelly.
i02323089
Engine Mounts - Inspect
Note: The engine mounts may not have been
supplied by Perkins. Refer to the OEM information for
further information on the engine mounts and the
correct bolt torque.
Inspect the engine mounts for deterioration and for
correct bolt torque. Engine vibration can be caused
by the following conditions:
Incorrect mounting of the engine
Deterioration of the engine mounts
Loose engine mounts
Any engine mount that shows deterioration should be
replaced. Refer to the OEM information for the
recommended torques.
i05909059
Engine Oil Level - Check
Hot oil and hot components can cause personal
injury. Do not allow hot oil or hot components to
contact the skin.
Illustration 41 g01165836
(Y) Min mark. (X) Max mark.
Illustration 42 g02173847
(L) Min mark. (H) Max mark.
NOTICE
Perform this maintenance with the engine stopped.
Note: Ensure that the engine is either level or that the
engine is in the normal operating position in order to
obtain a true level indication.
Note: After the engine has been switched OFF, wait
for 10 minutes in order to allow the engine oil to drain
to the oil pan. Then, check the oil level.
66 SEBU7833
Refill Capacities
Engine Ground - Inspect/Clean