Table 5
Acceptable Water
Property
Maximum Limit
Chloride (Cl) 40 mg/L
Sulfate (SO
4
) 100 mg/L
Total Hardness
170 mg/L
Total Solids
340 mg/L
Acidity pH of 5.5 to 9.0
For a water analysis, consult one of the following
sources:
Local water utility company
Agricultural agent
Independent laboratory
Additives
Additives help to protect the metal surfaces of the
cooling system. A lack of coolant additives or
insufficient amounts of additives enable the following
conditions to occur:
Corrosion
Formation of mineral deposits
Rust
Scale
Foaming of the coolant
Many additives are depleted during engine operation.
These additives must be replaced periodically.
Additives must be added at the correct concentration.
Over concentration of additives can cause the
inhibitors to drop out-of-solution. The deposits can
enable the following problems to occur:
Formation of gel compounds
Reduction of heat transfer
Leakage of the water pump seal
Plugging of radiators, coolers, and small passages
Glycol
Glycol in the coolant helps to provide protection
against the following conditions:
Boiling
Freezing
Cavitation of the water pump
For optimum performance, Perkins recommends a
1:1 mixture of a water/glycol solution.
Note: Use a mixture that will provide protection
against the lowest ambient temperature.
Note: 100 percent pure glycol will freeze at a
temperature of −13 °C (8.6 °F).
Most conventional antifreezes use ethylene glycol.
Propylene glycol may also be used. In a 1:1 mixture
with water, ethylene and propylene glycol provide
similar protection against freezing and boiling. Refer
to Table 6 and refer to table 7 .
Table 6
Ethylene Glycol
Concentration Freeze Protection
50 Percent
−36 °C (−33 °F)
60 Percent
−51 °C (−60 °F)
NOTICE
Do not use propylene glycol in concentrations that
exceed 50 percent glycol because of the reduced
heat transfer capability of propylene glycol. Use ethyl-
ene glycol in conditions that require additional protec-
tion against boiling or freezing.
Table 7
Propylene Glycol
Concentration Freeze Protection
50 Percent
−29 °C (−20 °F)
To check the concentration of glycol in the coolant,
measure the specific gravity of the coolant.
Coolant Recommendations
ELC Extended Life Coolant
SCA Supplement Coolant Additive
ASTM American Society for Testing and
Materials
The following two coolants are used in Perkins diesel
engines:
Preferred Perkins ELC
Acceptable A commercial heavy-duty antifreeze
that meets “ASTM D6210 specifications
48
SEBU9074-01
Maintenance Section
Fluid Recommendations