3
32 User’s Handbook, TSL 4186E, Issue 2
4012/16 Diesel
Normal starting and shutdown procedure
Normal starting
1 Turn the keyswitch to the start position. The engine should start immediately.
2 Release the keyswitch.
3 Check the instrument panel readings.
4 Run the engine for a minimum of 15 seconds before applying load.
5 If the engine does not start within a few minutes then stop cranking and allow the engine to stop rotating.
6 Wait 10 seconds and try again.
Note: If after three attempts the engine does not start, investigate the cause.
Normal shutdown
1 Disengage the engine load.
2 Run the engine at no load for 5 minutes.
Note: This will allow the circulating lubricating oil to dissipate heat from the turbocharger.