D. Economy
i.Purpose: Adjust brightness level for reducing power consumptions
ii.No optimization by Smart Image.
iii.Design:
1. Brightness level set to 70%, a little higher brightness level than laptop PC, fine tune brightness level
before DVT exit.
2. Color temperature set to 6500K.
3. Gamma Table is turn on.
E. Off
i. Purpose: No optimization by SmartImage.
ii. Design:
1. This will follow user OSD setting. If any change by user, it will be saved. When switch back from other
SmartImage profiles, it will go back to last saved setting.
2. Gamma Table is turn on to reduce bad color tracking.
3.15.1.7Demo mode
A. Purpose: Built-in demo mode for sales in-store demo.
B. Design:
i. Dynamically split screen to 2 vertical frames with one vertical white line. The line width is 2 pixels. The
left frame will be enhanced by SmartImage and right frame remains original performance.
ii. There is OSD showing “SmartImage On” in left frame and “SmartImage Off ” in right frame.
iii. The OSD word color is white with transparent background.
C. The demo profile will be “entertainment profile setting.
D. Hot keys to trigger:
Press [SmartImage] 3 seconds or more to trigger the demo mode. When demo mode is On, press 3
seconds or more to turn off the demo mode. When the demo mode is enabled, the blue LED will
flash until demo mode disabled.(N/A for this model)
3.16 Smart Response
Gray to Gray Response time : 2ms (Avg.)
4. Visual characteristics
4.1 Test conditions
Unless otherwise specified, this specification is defined under the following conditions.
(1) Input signal : As defined in 3.3, 1680 x 1050
non-interlaced mode (1680 x 1050@60Hz 146.25MHz), signal
sources must have 75 ohm output impedance.
(2) Luminance setting : controls to be set to 300 nits (typical) with
full screen 100 % duty cycle white signal
(3) Warm up: more than 30 minutes after power on with signal supplied.
(4) Ambient light: 400 -- 600 lux.
(5) Ambient temperature: 20 ± 5 °C
4.2 Brightness
Follow Panel specification.
4.3 Image size
Actual display size 376.3 x 301.1 mm