HUDSON 8
94
3.2.3 USB Cable (High Full Speed)
Length : 1.8 M +/- 50 mm (Max.)
Connector type : USB- B Plug (Input)
USB- A Plug (Output)
Pin Assignment:
Pin No. Description
1 VBUS
2 Data+
3 Data-
4 GND
3.3 Timing requirement
Factory Preset mode definition :
1. Perfect FOS while presenting all required timings.
2. Required timings need to be specified in User's Manual
Preset mode definition :
1. Need to support those timings.
2. Perfect FOS after auto adjustment.
User mode
1. Can save those timing that not in Preset mode and can be showed (not over scalar or Panel spec.)
2. It needs to reserve the 12 timings space in memory size.
3.3.1 Mode storing capacity
Factory preset modes : 14
Preset modes : 42
User define modes : 12
Note: 1. Screen displays perfect picture at 14 factory-preset modes.
2. Screen displays visible picture with OSD warning when input modes are the 45 preset modes.
3.3.2 Factory preset modes (14 modes)
Factory modes and preset modes are defined in the enclosed timing table file.
200CW8 Preset Mode
Item H.Freq. (KHz) Mode Resolution V.Freq. (Hz)
1 31.469 IBM VGA 10H 640x350 70.086
2 31.469 IBM VGA 3H 720x400 70.087
3 31.469 IBM VGA 12H 640x480 59.94
4 35 MACINTOSH 640x480 67
5 37.861 VESA 640x480 72.809
6 37.5 VESA 640x480 75
7 35.156 VESA 800x600 56.25
8 37.879 VESA 800x600 60.317
9 48.077 VESA 800x600 72.188
10 46.875 VESA 800x600 75
11 49.7 MACINTOSH 832x624 75
12 56.4 - 960x720 75