TABLE 4
POWER SUPPLY SPECIFICATIONS
Input Voltage Range 90 to 265 VAC sinusoidal for all models
Input Frequency Range 47 to 63 Hz over the specified input voltage range
Power Consumption Refer to Table 5 for details.
Line Fuse The AC input shall be fused and become electrically open as a result
on an unsafe current level. The fuse may not be user replaceable.
Initial Cold Start The power supply shall start and function properly when under full load,
with worst case conditions of input voltage, input frequency,
operating temperature, and cold backlight lamps.
Inrush Current < 30 A when operated at 120 VAC,
< 50 A when operated at 220 VAC.
Hot Start Cycle The power supply shall not be damaged when switched ON for one second
and OFF for one second for seven consecutive times after operating
for one hour at full load, 25°C, and nominal input line voltage.
Under Voltage The power supply shall contain protection circuitry such that the application
of an input voltage below the minimum specified value shall not
cause damage to the power supply unit nor cause failure of the input fuse.
Line Transient The power supply shall operate within IEC 801-4 ( ± 1 kV) and IEC 801-5 ( ± 2 kV)
for the domestic U.S. version. The UPS power supply shall operate and comply with
CE mark regulations for all international versions.
Leakage Current Maximum leakage current is 500mA at 120VAC input.
2.2.2 Power Cord
IEC C-13/C-14 (Standard) type male power receptacle for connection to mains power. The “Mickey
Mouse” C-5/C-6 type of connector is not allowed. The power cord, exact type to be supplied in the
appropriate Option Kit, shall be black and have length of 1.8 ± 0.05 meters.
2.2.3 Power Management Onset
When the CPU signals the monitor to enter a reduced power state (the monitor shall blank the video
within 200 milliseconds, display the OSD message “Going to Sleep”, and then enter the reduced
power state approximately 3 seconds after the OSD message appears. If the Power Saver feature is
set to Off, then the “No Input Signal” OSD message shall be continuously displayed with a moving
OSD box to prevent image retention on the LCD panel. The monitor shall recover from sleep mode
within 3 seconds as measured by stable syncs and Video On and Backlight On.
TABLE 5
POWER CONSUMPTION
CPU State Monitor State Maximum Power
(Watts)
Power Switch LED Color
Full Power Full Power 25 Green
Sleep Sleep 2 Amber
- Switch Off 2 (LED off)