5.1 ps2000_close_unit
int16_t ps2000_close_unit
(
int16_t handle
)
Shuts down a PicoScope 2000 Series oscilloscope.
Applicability
All modes
Arguments
handle: the handle, returned by ps2000_open_unit, of the oscilloscope
being closed
Returns
non-zero: if a valid handle is passed
0: if handle is not valid