EasyManuals Logo
Home>pico Technology>Test Equipment>PicoScope 2000 Series

pico Technology PicoScope 2000 Series Programmer's Guide

pico Technology PicoScope 2000 Series
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #23 background imageLoading...
Page #23 background image
API Functions
23Copyright © 20062022 Pico Technology Ltd. All rights reserved.ps2000pg.en-12
PicoScope 2000 Series Programmer's Guide
5.5 ps2000_get_streaming_values_no_aggregation
uint32_t ps2000_get_streaming_values_no_aggregation
(
int16_t handle,
double *start_time,
int16_t *pbuffer_a,
int16_t *pbuffer_b,
int16_t *pbuffer_c,
int16_t *pbuffer_d,
int16_t *overflow,
uint32_t *triggerAt,
int16_t *trigger,
uint32_t no_of_values
)
This function retrieves raw streaming data from the driver's data store after fast streaming
has stopped.
Before calling the function, capture some data using fast streaming, stop streaming using
ps2000_stop, and then allocate sufficient buffer space to receive the requested data. The
function will store the data in your buffer with values in the range PS2000_MIN_VALUE to
PS2000_MAX_VALUE. The special value PS2000_LOST_DATA is stored in the buffer when data
could not be collected because of a buffer overrun. (See Voltage ranges for more details of
data values.)

Table of Contents

Other manuals for pico Technology PicoScope 2000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the pico Technology PicoScope 2000 Series and is the answer not in the manual?

pico Technology PicoScope 2000 Series Specifications

General IconGeneral
Brandpico Technology
ModelPicoScope 2000 Series
CategoryTest Equipment
LanguageEnglish

Related product manuals