Diagnostics
Getting started Modular safety relay,myPNOZ
1005615-EN-02
| 29
Module
LED
Function LED Meaning Remedy
Flashing
orange
green
Output LED on
a module is
flashing green
Configuration error at the output:
– Position of the rotary switch n
does not match the saved con-
figuration
– Position of the rotary switch t[s]
does not match the saved con-
figuration
When saving of the current configur-
ation has failed:
– Rotary switch n or t[s] is in an
intermediate position, which is
not permitted
Check the position of the rotary
switches, configure the position and
save the configuration
– Check the position of the rotary
switch and correct the position
“Internal error” error message
If this error occurs
} All safe outputs are switched off
} All signal outputs are switched off
} Communication is interrupted and subsequent modules indicate a communication error
This error cannot be rectified. Please exchange the affected module or contact Pilz.
Module
LED
Function LED Meaning Remedy
Lights up
red
All LEDs off
Internal error Exchange module or contact Pilz
Communication error message
Communication errors occur when communication between the head module and expan-
sion module is disrupted. In the event of this type of error
} All safe outputs are switched off
} All signal outputs are switched off
Once the connection is stable again and no further errors are present, myPNOZ switches to
a STOP state. The rotary switch System must first be set to Stop and then to Run.
Module
LED
Function LED Meaning Remedy
Flashes
red-orange
All LEDs off
No connection to the head module Check whether the bus connectors
are firmly inserted between the mod-
ules