PKB-M, PKB-MS Operating Manual16
Operation
Peak Cur
XXX.XA
Peak current
XXX.X Peak value of the braking current when the brake contactor
energises or de-energises (switching current of the brake
contactor)
So as not to damage the free wheel diode, the switch-on current should
not exceed 100 A.
INFORMATION
To reduce the switch on current, increase safety time t
v1
.
To reduce the switch off current, increase safety time t
v3
. This increases
the life of the brake contactor.
N XX.XA
A YY.YA
Braking current
XX.X set braking current
YY.Y measured effective value of the braking current
Max XXX#
A YYY# Z
Standstill threshold
Only on units with standstill detection
XXX highest level of the standstill signal
YYY current level of the standstill signal
Z 1, 2, 3 or 4; Step in the control logic (see standstill menu and
sub-menu)
N XXX°Ci
A YYY°Ci
Heatsink temperature
XXX set maximum value of the heatsink temperature
YYY current value of the heatsink temperature
N XXXkΩe
A YYYkΩe
Motor temperature
XXX set maximum value of the external PTC-thermistor
YYY current value of the external PTC-thermistor