PKB-M, PKB-MS Operating Manual 17
ENGLISH
Version
Version
Ver. No.
XXXXX
Version number
XXXXX Version number (hardware and software status)
XXXXYYYY
ZZZZZZZZ
Version
XXXX 240V: 240 VAC unit
415V: 415 VAC unit
460V: 460 VAC unit
550V: 550 VAC unit
600V: 600 VAC unit
YYYY /15A: 15 A unit
/30A: 30 A unit
ZZZZZZZZ ext. BC: Unit with external brake contactor
int. BC: Unit with internal brake contactor
PKBM Typ
XXXXXXXX
Type
XXXXXXXX Standard: standard version
Aut.Stop: version with automatic standstill detection
curr.No.
XXXXXXXX
Production number
XXXXXXXX serial number
Ign.-Pt.
o XXXXX#
Firing time point
XXXXX Current firing time point of the thyristor control
E-PWR: Voltage at terminals L1 and L2 is missing.
Function control
After setting the braking time and the braking current, a test process is
carried out.
If you have selected brake until standstill, repeat the test several times
with a cold and warm motor.
• Check the switch-on current when the brake contactor energises (see
peak current display).
• Check the sequence on the LCD display (see process display).