PSEN cs3.1n
Operating Manual PSEN cs3.1n
22172-EN-06
| 8
For your safety
WARNING!
Loss of safety function due to manipulation of the interlocking device
Manipulation of the interlocking device may lead to serious injury and death.
– You should prevent any possibility of the interlocking device being
manipulated through the use of a spare actuator.
– Keep the substitute actuator in a safe place and protect it from unau-
thorised access.
– If spare actuators are used, these must be installed as described in
Installation [ 15].
– If the original actuators are replaced with substitute actuators, the ori-
ginal actuators must be destroyed before disposal.
} Do not remove the connector's protective cap until you are just about to connect the unit.
This will prevent potential contamination.
Unit features
} Transponder technology for presence detection
} Pilz coding type: Coded
} Dual-channel operation
} 2 safety outputs
} LED display for:
– State of the actuator
– Supply voltage/fault
} 1 direction of actuation
} 5-pin M12 male connector