PSEN sl-0.5p 1.1
Operating Manual PSEN sl-0.5p 1.1
21904-EN-10
33
Safety characteristic data
NOTICE
You must comply with the safety-related characteristic data in order to
achieve the required safety level for your plant/machine.
Operating
Mode
EN ISO
13849-1:
2015
PL
EN ISO
13849-1:
2015
Category
EN 62061
SIL CL
EN 62061
PFH
D
[1/h]
IEC 61511
SIL
IEC 61511
PFD
EN ISO
13849-1:
2015
T
M
[year]
2-ch. OSSD PL e Cat. 4 SIL CL 3 3,29E-09 SIL 3 1,72E-04 20
All the units used within a safety function must be considered when calculating the safety
characteristic data.
INFORMATION
A safety function's SIL/PL values are not identical to the SIL/PL values of
the units that are used and may be different. We recommend that you use
the PAScal software tool to calculate the safety function's SIL/PL values.
Order reference
Order reference for safety gate system
Product type Features
Connection
type Order No.
PSEN sl-0.5p 1.1 / PSENsl-0.51unit Safety gate system, coded M12, 8-pin con-
nector
570500
PSEN sl-0.5p 1.1 / PSENsl-0.5fm1unit Safety gate system,
coded, with free-moving
actuator
M12, 8-pin con-
nector
570560
Accessories
Product type Features Order no.
PSEN sl bracket swing door Mounting bracket for swing gates and folding gates 570 550
PSEN sl bracket sliding door Mounting bracket for sliding gates 570 551