PSEN sl-1.0p 1.1/1.1 VA
Operating Manual PSEN sl-1.0p 1.1/1.1 VA
1003821-EN-12
19
} Installation measures in accordance with EN ISO 14119
– Use permanently secured safety screws with a flat head to attach the safety switch
and the actuator (e.g. cheese-head or pan head screws) or rivets.
– Installation of the safety switch and actuator must be concealed.
} Alignment errors of the guard must not adversely affect the safety function of the guard.
INFORMATION
Mounting brackets are available as accessories [ 38].