Installation
} The safety gate system can be installed on left or right-hinged swing gates or on sliding
gates.
WARNING!
Potential loss of safety function due to gross manipulation
Depending on the application, serious injury or death may result.
Use appropriate installation measures to prevent
The wiring being modified.
A short circuit being generated on the connector.
The possibility of using a second actuator to open the safety gate.
CAUTION!
The unit's properties may be affected if installed in an environment contain-
ing electrically or magnetically conductive material. Please check the oper-
ating distances and the assured release distance.
} Safety switches and actuators must be positioned so that they are secured against a
change of position.
} Also note the max. angular offset (see Technical details: System with normal
actuator [ 27], System with free-moving actuator [ 30], System with normal ac-
tuator and stainless steel base plate [ 34]).
} The access to the safety switch and actuator has to be possible for maintenance and
checking the correct operation.
} Use reliable fastening elements. A tool is to be required to loosen the fastening ele-
ments.
} Prevent self-loosening of the fastening elements of safety switch and actuator.
} The fastening of safety switch and actuator has to be sufficiently stable to ensure the
proper operation of the safety switch and the actuator.
} Prevent the safety switch and actuator being exposed to heavy shock or vibration
} Circumvention of the safety switch in a reasonably foreseeable manner must be pre-
vented.