PZE X4.1P
Operating Manual PZE X4.1P
1003203-EN-09
| 5
INFORMATION
This gives advice on applications and provides information on special fea-
tures.
Safety
Intended use
The contact expansion module PZE X4.1P meets the requirements of EN 60947-5-1 and
EN 60204- 1. It is an expansion module for increasing the number of contacts available on
a base unit. Base units are all
} Safety relays with feedback loop
} programmable safety systems with feedback loop
} Units with OSSD semiconductor outputs and feedback loop
The max. achievable safety level depends on the base unit. The expansion module may not
exceed this. The safety-related characteristic values stated under safety-related character-
istic data [ 20] can only be achieved if the base unit also exhibits these safety charac-
teristic values.
The following is deemed improper use in particular
} Any component, technical or electrical modification to the product,
} Use of the product outside the areas described in this manual,
} Use of the product outside the technical details (see Technical details [ 12]).
NOTICE
EMC-compliant electrical installation
The product is designed for use in an industrial environment. The product
may cause interference if installed in other environments. If installed in other
environments, measures should be taken to comply with the applicable
standards and directives for the respective installation site with regard to in-
terference.
Safety regulations
Safety assessment
Before using a device, a safety assessment in accordance with the Machinery Directive is
required.
The product as an individual component fulfils the functional safety requirements in accord-
ance with EN ISO 13849 and EN 62061. However, this does not guarantee the functional
safety of the overall plant/machine. To achieve the relevant safety level of the overall plant/
machine’s required safety functions, each safety function needs to be considered separ-
ately.