The Diagnostics Display has two modes of operation:
Status and Fault. If a fault occurs, the display will scroll
the fault message until the “FN1” fault reset button is
pushed, even if the cause of the fault is corrected and/
or you reset the power.
Status Display Messages
Normal Operation
TEST Testing internal systems
RST Unit waiting for Push of RESET button
(located on control module power supply
board middle left hand side). If you push
the Reset button during normal operation,
the unit will go RED and display RST, push
again and the unit will start up.
RDY Normal operation, no operations selected.
RdyE External relay checking feature active
RdyM Mute-Out option enabled
RdyL Normal, Latching Relay option software
selected. Used to reset guard penetration.
RdyF Weld ash enabled
Obstruction
03 > This is an example of 15 or more beams
blocked starting at 3” up from connector
pylon.
153 This is an example of 3 beams out starting
1.5” up from connector end of pylon.
SBLK Slave miroprocessor detected blockage
when the Master did not. Some of the
receiver signals are so weak that the
leading edge of the pulse is missed by the
Slave, but the trailing edge is not missed
by the Master. Realign the pylons.
FLIP Master microprocessor is getting intermittent
blockage of the curtain, due to weak signals
and is ip-opping between trying to go
GREEN and to RED. Re-align the pylons.
Floating Blank
FBxy Floating Blank, x indicates # of beams
oating and y indicates option selected or
number of beams broken. Yellow LED on
the control unit will also light up.
OBST Floating Blank Obstruction; more than
one object was detected in the curtain.
Optional conguration allows two objects
for applications where the piece part is bent
twice.
Auto Blank
ABxy Auto Blank, x indicates number of beams
blanked by object, y indicates option
selected or number of beams broken in
Mode 3. If no object found during program,
the display will read RDY.
In future software versions, the blocked
pattern will be stored in permanent memory
to allow you to power down without having
to reprogram in the object.
PENT Auto Blank in Mode 1 and/or Resettable
Latching Relay option in which the curtain
was penetrated. By moving the AB
keyswitch into OFF/RESET, you can clear
this but by moving the keyswitch into MODE
2 or 3 you can clear the PENT without
reprogramming in the AB object.
If using the Resettable Latching Relay
option, you can reset the cycling the
CLOSE contacts S5 located on the door of
the control unit. This is where you would
connect your remote reset push button.
SIZE Auto Blank programmed object exceeded
eight beams total. Optional conguration
can increase or decrease this number.
MOVE Auto Blank object moved during normal
operations, exposing beams that were
previously blocked. This can occur if the
object is not fully blocking one of the beams
its covering. Optional conguration can
ignore movements of the object.
Mute-Out
MUTE Guard has gone into by-pass mode
Cincinnati Interface
CINN When your Cincinnati interface applies
+24VDC to terminals 5 & 6, the curtain wil
go RED.
Appendix “A”
Diagnostics and Troubleshooting
A-2