EasyManua.ls Logo

Pioneer Eclipse PE300BU - Alarm Codes

Pioneer Eclipse PE300BU
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Alarm Codes (Traction Model Only)
*Given the following alarm codes, troubleshooting should only be done by Amano Pioneer Eclipse Factory Certified
Technician. A programming handset may be required for troubleshooting.
18
Number of
Flashes
Description Possible Cause
1 (fast) Low Battery Voltage
The battery needs charging or there is a bad connection
to the battery. Check the connections to the battery. If the
connections are good, try charging the battery.
1 (medium) Handle lever engaged at key on
Disengage the handle lever, key off and key back on to
clear
1 (slow) Machine Time Out
The machine has been left with the key on. Turn the key off
and then back on again.
2 Motor Disconnected
The motor has a bad connection. Check all the
connections and leads between the motor and the
controller.
3 Motor Wiring Trip
The motor has a short circuit to a battery. Check all the
connections and leads between the motor and the battery.
6Inhibit Active
The controller is being inhibited from driving. Check the
state of the Inhibit unputs.
7 Throttle Trip
A throttle trip is indicated. Make sure that the throttle is in
the rest position before switching on the vehicle.
8 Possible Controller Trip
A possible controller trip is indicated. Make sure that all
connections are secure.
9 Solenoid Brake Trip
The parking brakes have a bad connection. Check the
parking brake and motor connections. Make sure the
controller connections are secure.
10 High Battery Voltage
An excessive voltage has been applied to the controller.
This is usually caused by a poor battery connection. Check
the battery connections.