6.9 OUTLINE OF COMMANDS
GET Commands
GS1: Returning information on the model and the version of the software
GPM: Returning the data of the PDP pulse meter
Breakdown of the data on the display
Order
Data Size
1 Data on the display 3 bytes
2 Version of the module microcomputer 4 bytes
3 Version of the IC4-MANTA 4 bytes
4 Sequence version (50VIDEO) 4 bytes
5 Sequence version (50PC) 4 bytes
6 Sequence version (43VIDEO) 4 bytes
7 Sequence version (43PC) 4 bytes
8 Version of the IF microcomputer 4 bytes
9 Version of the main microcomputer 4 bytes
10 Version of the IC3-MANTA 4 bytes
11 Version of the OSD 4 bytes
12
Version of the DTV microcomputer
(only for models for North America)
4 bytes
13
Version of the CC microcomputer
(only for models for North America)
4 bytes
14
Version of the TEXT microcomputer
(only for models for Europe)
4 bytes
Order
Data Size
1 Pulse meter (Block area 1) 10 bytes
2 Pulse meter (Block area 2) 10 bytes
3 Pulse meter (Block area 3) 10 bytes
4 Pulse meter (Block area 4) 10 bytes
5 Pulse meter (Block area 5) 10 bytes
GPC: Returning the cumulative number of times the power to the PDP was turned on
• Commands for clearing the logs
Order
Data Size
1 Power-on counter 8 bytes
Data Model
HD5 PDP-504HD series
HD4 PDP-434HD series
Note: Refer to the service manual of the panel.
Parameter
Corresponding
RS-232C Command
PD INFO CPD
SD INFO CSD
NG INFO CNG
HOUR METER CHM
MR HOUR METER
(Only for the system model)
CHR
PULSE METER CPM
P ON COUNTER CPC