3-20
PAGE
ALPHA Trainer LSA
Pilot Operating Handbook
POH-162-00-40-001
PAGE REV. 0
SECTION 3
EMERGENCY PROCEDURES
1 Groundspeed indicator
+10 KTS for procedures, observe
winds
3.13 ELECTRIC TRIM FAILURE
Any failure or malfunction of the electric trim can be overridden by use of
the control stick. If runaway trim is the problem, cut the circuit by pulling the
circuit breaker and land as soon as conditions permit.
1 Airplane Control
GRASP STICK,
MAINTAIN MANUALLY
If problem is not corrected:
3 Elevator Trim Circuit Breaker PULL
4 Throttle Lever AS REQUIRED
5 Control Stick MANUALLY HOLD PRESSURE
6 Land AS SOON AS PRACTICAL
3.14 BATTERY OVERVOLTAGE / MALFUNCTION
If the standard lead-acid battery is installed and overvoltage occurs (over 14.4
V), the battery must be disconnected from the system to prevent adverse
eects.
1 MASTER BAT switch OFF
WARNING:!Engine restart is not possible with MASTER BAT switch in
OFF position!
The EarthX battery disconnects itself in case of over- or undervoltage.
NOTE: When EarthX battery type is installed, battery over-voltage, low volt-
age or other battery system malfunctions, are additionally indicated by the
Batt Caution light on the switch panel. The rate at which the light flashes,
indicates what type of malfunction or error is in question. Please refer to
EarthX ETX lithium battery user’s manual for additional information about
how to troubleshoot any battery errors/malfunctions
.