Defective HSI.
Defective HSI module.
Machine makes Booming sound.
Defective Blower Relay.
Defective Blower.
Burners try to ignite but Blower does NOT come on.
Defective HSI module.
Defective HSI.
Defective Burner.
Incorrect Gas or Air pressure.
Burners come ON but shut down after a few seconds.
Defective HSI module.HSIs blow but Burners do NOT come on.
Defective HSI.
Defective HSI module.
Blower comes ON but Burners do NOT light.
POSSIBLE CAUSESSYMPTOM
RPB14:
SCHEMATICS:
1700213Schematic, TSTAT Digital Gas - RPB ........................
2700212Schematic, Gas - RPB w/3600 - 2 TK Computer ................
2700211Schematic, Gas - RPB w/3600 - 1 TK CMPTR. .................
2700210Schematic, Gas - ALL Options w/3600 2 TK CMPTR. .............
2700209Schematic, Gas - ALL Options w/3600 1 TK CMPTR. .............
1700208Schematic, Gas - ALL Options w/Digital T-Stat
..................
# PagesSchematic Drawing #Description