4-13
Move or tighten the
probe.
NO
YES
Is the
temperature probe loose
or in the wrong
location?
Check contactors K7 thru K10. Check
wiring for loose connections. Check
Continuity between the grey lead on
each contactor and the grey lead to
the HEATING light.
NO
Replace the defective
heating elements
NO
YES
Check heating
elements as described
in 4.3. Are they all
good?
G
Replace the blown fuses.
Are any of the
heating elements
fuses blown?
YES