IMPORTANT FOR FUTURE REFERENCE
Please complete this information and retain this manual
for the life of the equipment:
Model #: ___________________________
Serial #: ___________________________
Date Purchased: ____________________
ENGLISH
Installation & Operation Manual
REDUCED OIL VOLUME
FRYING SYSTEM
Covering
Models
SSHLV14, SSHLV184 SERIES
D
E
I
F
I
T
R
E
C
D
E
S
I
G
N
C IRE T IF E D
L20-407 rev. 2 (12/14)

Table of Contents

Questions and Answers

  • T
    Tyrone SmithAug 14, 2025
    What to do if controller does not activate on Pitco SSHLV184 Fryer?
    • A
      Ashley CallahanAug 15, 2025
      If the controller on your Pitco Fryer doesn't activate, there could be several reasons: * **No power to appliance:** Check the main building power supply. * **Controller not turned on:** Ensure the controller is turned on. * **Power cord loose:** Connect the power cord securely. * **Circuit breaker tripped:** Reset the circuit breaker. If the appliance fuse has blown, contact an authorized service company.
  • K
    Kristy MurrayAug 18, 2025
    What to do if Pitco SSHLV184 Fryer appliance will not heat up?
    • K
      Kevin RothAug 18, 2025
      If your Pitco Fryer isn't heating up, it could be due to: * **High temperature limit tripped:** Allow the appliance to cool down and then reset the high temperature limit. * **SCBS thermal limit switch tripped:** Depress the button on the thermal limit switch to reset it. If the problem continues, contact an authorized service company.
  • M
    Michelle AndersonAug 21, 2025
    What to do if Pitco Fryer filter pump does not activate?
    • J
      Jeremy GibsonAug 21, 2025
      If the filter pump on your Pitco Fryer does not activate, reset the circuit breaker or allow the motor to cool, then press the RED reset button on the motor.
  • Y
    youngkaitlinAug 25, 2025
    Why is oil returning slowly to the Pitco SSHLV184 tank?
    • A
      Amanda OliverAug 25, 2025
      If oil or shortening is returning to the tank slowly or not at all in your Pitco Fryer, consider these possible causes: * **Dirty filter paper:** Change the filter paper. * **Dirty strainer cap:** Remove and clean the strainer cap. * **Filter pan not fully pushed in:** Ensure the filter pan is completely pushed in.
  • L
    Laura Estes MDAug 27, 2025
    Why are there excessive air bubbles in Pitco SSHLV184 oil?
    • D
      David StuartAug 27, 2025
      Excessive air bubbles in the oil being returned to the tank of your Pitco Fryer can be caused by: * **Loose pickup tube screen:** Tighten the pickup tube screen cap. * **Missing pickup tube screen cap:** Locate and install the pickup tube screen cap. * **Filter pan not fully pushed in:** Push the filter pan in completely to ensure a proper connection.
  • C
    Charlotte HerreraAug 31, 2025
    What to do if Pitco SSHLV184 Fryer shows 'DRAINING' when valve is closed?
    • G
      Gilbert DunnAug 31, 2025
      If your Pitco Fryer's computer controller still displays 'DRAINING' even when the drain valve is closed, it could be due to: * **Drain valve handle not completely closed:** Verify that the drain valve handle is completely closed. * **Improperly adjusted drain switch:** Contact an authorized service company.
  • A
    Anthony HarringtonSep 3, 2025
    What to do if Pitco SSHLV184 computer display is off?
    • A
      Andrew ThomasSep 3, 2025
      If the computer display on your Pitco Fryer is off and cannot be turned on, contact an authorized service company, as this could indicate a faulty computer.
  • J
    Jessica BrownSep 6, 2025
    What to do if Pitco SSHLV184 has drain valve interlock?
    • R
      Robert SanchezSep 7, 2025
      If your Pitco Fryer shows a drain valve interlock: * Turn the computer OFF (if it's not already OFF). * Close the tank drain valve and fill the tank with oil or shortening. * Turn the computer ON.
  • G
    gregory53Sep 10, 2025
    What to do for Pitco Fryer power failure?
    • D
      Daniel KempSep 10, 2025
      In case of a power failure with your Pitco Fryer: * Wait five minutes after the power is restored before attempting to restart the appliance. * To restart the appliance, follow the start up procedure.

Summary

Theory of Operation

Installation

Installation Clearances

Specifies required distances from combustible/non-combustible materials for safety.

Leveling the Fryer - Legs;Casters

Procedure for leveling the appliance using its legs or casters for stability.

Gas Connection

Guidelines for connecting the gas supply according to local and national codes.

Quick Disconnect Connection

Requirements for quick disconnect devices for gas appliances with casters.

Fuel Supply Line Leak and Pressure Testing

Procedure for testing gas supply lines for leaks and correct pressure.

Installation Setup

Conforming the installation to applicable local and national codes.

Electrical Connections

Guidelines for connecting the appliance to the correct electrical supply.

Ventilation and Fire Safety Systems

Importance of proper ventilation and fire safety systems for safe operation.

Initial Adjustments

Adjustments needed after installation for proper appliance performance.

Operation

Filling the Fry Pot

Procedure for correctly filling the fry pot with liquid shortening.

Filling the Tank with Liquid Shortening

Detailed steps for filling the appliance's tank with liquid shortening.

Appliance Start Up

Computer Controller Operation

Quick Strain Filtering Filter Soon Light Flashing

Appliance Shutdown

Preventative Maintenance

Daily Preventative Maintenance

Daily tasks to keep the equipment safe and performing well.

Annual;Periodic Preventative Maintenance and Inspection

Annual inspection and maintenance by a qualified technician.

Troubleshooting

Fryer Troubleshooting Chart

Common fryer problems and their corrective actions.

Filter Troubleshooting Chart

Common filter system problems and their corrective actions.

Computer & Digital Controller Displays

Understanding messages and displays on the digital controller.

Pitco SSHLV184 Series Specifications

General IconGeneral
BrandPitco
ModelSSHLV184 Series
CategoryFryer
LanguageEnglish