INSTALLATION & OPERATIONAL SSHLV SERIES MANUAL
5.15. BEEPER VOLUME AND TONE:
Volume and Tone of the beeper alarm may be changed in this section. Volume ranges are 1,2 and 3,
where 3 is the loudest setting.
With display showing [PROGRAM], press the product key [0].
Display will show [SELECT] [OPTIONS]. Press product key 3, display shows
[VOLUME n] [BEEPER]. Use the product key [0] to scroll through choices (n= 1,2,3,
or T). Beeper volume will change as each selection is made.
If “T” is selected an additional display is shown, [TONE n] [BEEPER]. Use the product
key [0] to scroll through choices (n= 1,2,3). Beeper tone will change as each selection is made.
Press [P] key to save choice. Display shows [PROGRAM].
5.16. LANGUAGE SELECTION:
With display showing [PROGRAM], press the product key [0].
Display shows [SELECT] [OPTIONS].
Press product key 4, display shows [ENGLISH] [LANGUAGE].
Use the product key [0] to scroll through choices (ENGLISH, ESPANOL, FRANCAIS,
DEUTSCH, HOLLAND).
Press [P] key to save choice. Display shows [PROGRAM].
5.17. MELT CYCLE TYPE:
This adjustment allows selection of the melt cycle type, or, disabling the melt cycle requirement when
starting the appliance from a cold start.
With display showing [PROGRAM], press the product key [0].
Display will show [SELECT] [OPTIONS].
Press product key 5, display shows [LIQUID], the default setting.
Use the product key [0] to scroll through choices (liquid, solid, no melt).
Press [P] key to save choice. Display will again return to [PROGRAM].
5.18. RECOVERY TEST VALUE:
This controller maintains a record of heat up times for the appliance. A
poorly running appliance will have increased recovery times stored in
this display. There is no selection done here, just the display of
recovery time values.
With display showing [PROGRAM], press the product key [0].
Display shows [SELECT] [OPTIONS].
Press product key 6; display will show [RECOVERY] [TEST].
Press the product key [0]. Display will show [FnnnLyyy], where nnn is
the factory recovery value, and yyy is the last warm up recovery value.
After recording these values, press the [P] key. Display returns to
[PROGRAM].
5.19. CONTROL OR TIMER: (LEFT SIDE OF DUAL OR SINGLE VAT)
With display showing [PROGRAM], press the product key [0].
Display shows [SELECT] [OPTIONS].
Press product key 7; display will show [CONTROL].
Use the product key [0] to scroll through choices (Control, Timer).
Press [P] key to save choice. Display shows [PROGRAM].
Note: If timer is selected, heat control outputs are disabled, leaving only the timer
functions active. Do not make this selection on SSHLV fryer models.
L20-407 rev. 2 (12/14) 23

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pitco SSHLV184 Series and is the answer not in the manual?

Pitco SSHLV184 Series Specifications

General IconGeneral
BrandPitco
ModelSSHLV184 Series
CategoryFryer
LanguageEnglish

Related product manuals