4-15
YES
Check
interconnecting
wire.
NO
Replace the
probe.
Computer
functioning properly
for temperature
control.
NO
YES
Does the
computer display
indicate
PROB?
Is the probe
resistance correct?
Refer to 4.6 for probe
test procedure.
Is the oil
temperature less
than 70°F?
Raise the temperature of
the oil using the backup
thermostat. The problem
should correct itself.
YES
NO
Perform element
resistance check
asdescribed in 4-3.
NO
NO
YES
Check the
contactors as
described in 4.2. Are
the contactors
defective?
Replace the
defective
contactor.
YES
Determine why
fuses blew and
replace the blown
fuses.
Check
element fuses.
Are any of the
fuses open?
A CB
But Blanch Mode
switch in BLANCH
OFF.
NO
YES
If the fyer has a
Blanch Mode Swich
ensure that it is in BLANCH
OFF. Is the switch in
BLANCH OFF?
Check
interconnecting wire.