EasyManuals Logo

Pixsys ATR 421 User Manual

Pixsys ATR 421
108 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #16 background imageLoading...
Page #16 background image
16 ATR 421 - User manual
13
Whit controller in
STOP
it visualize the duration of the last cycle.
• In con guration it assigns a mnemonic code or a number to the
selected parameter.
During a cycle it allows to visulize cycling the setpoint and the
other data.
14
PRG
M
Whit controller in STOP allows to enter cycle modi cation and
con guration.
During a cycle, if pressed for 1 second, it allows to activate/de-
activate HOLD function.
15
STA
R
T
STO
P
Start/Stop a cycle.
In parameter con guration and cycle data modi cation, it is
used as exit key (ESCAPE).
16
O
K
Value or selected function con rmation.
6 Programming and con guration
There are two programming levels:
1. Cycles programming (for operator/user) means entering time/setpoint
values for each step of cycle.
2. Con guration (for manufacturer/installer of plant), to enter main par me-
ters (sensor type, output type, auxiliary output intervention type ext.).
6.1 Programming (or modifying) cycle data
With or without starting setpoint and timed auxiliary outputs.
The above speci cations underline the possibility given to the installer
(plant’s manufacturer) to choose the sequence of operations required for the
programming of a  ring cycle.
This paragraph includes all available options. In case that the installer de-
cides to choose a simpli ed programming with less options, it is highly re-
commended to prepare additional instructions specifying only the choosen
sequence.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pixsys ATR 421 and is the answer not in the manual?

Pixsys ATR 421 Specifications

General IconGeneral
BrandPixsys
ModelATR 421
CategoryController
LanguageEnglish

Related product manuals