LUB
9999H Set this value to “0” to disable the time
alarm of lub. oil
GREASE
9999H Set this value to “0” to disable the time
alarm of Lub. Grease
BELT
9999H Set this value to “0” to disable the time
alarm of belt.
LANG.SEL EN/CH EN
Set this value to “EN” , Display text in
English
Set this value to “CH” , Display text in
Chinese
NEW USER
PIN
****
****
Customer could modify the user
password
7、Factory Parameters
The factory parameters can be looked over and modified with manufacturer password, but its operation
method is the same as that of user parameters. Please refer to following table for main functions and
purposes.
Manufacturers enter the correct password
,
press set button, switch to the factory
parameters of the interface as follows
………
Factory parameters "run time", "phase sequence protection," "Frequency
Selection" and the time need check super password to changes.
8、Manufacturers and function
PARAMETER Initial Value Functions
MOTOR CUR
MAXIMUM
OVERLOAD VAULE OF
THE MOTOR /1.2
After the starting delay time, when the motor current
is greater than 1.2 times of the set value and less than
4 times of the set value, the unit will jump as per
overload feature.
FAN CUR
Maximum allowable
motor overload value/1.2
Same as above
ALARM T.
105℃
Pre-alarm when the temperature reaches this set value
STOP T.
110℃
Alarm when the air exhausting temperature reaches
this set value.
INPUT CODE
**
MOTOR CUR:100.0A
FAN CUR:010.0A
ALARM T:0105℃
STOP T:0110℃
STOP P:00.90MPa
MAX U.L.:00.85MPa
RUN TIME:001234H
LOAD TIME:001001H