Service - Menu
structure
Service settings
.
Boiler settings
CH and HU
W
settings
Mixer 1-
4
settings*
Show adv
enced setup NO / Y
ES
Restore default
s
settings
Touch screen
calibration
Boiler settings
Firing-
up
Output modulation
Burning off
Supervision
Lambda sensor
*
Thermostat sele
c
tion*
Min boiler te
mperature
Max boiler
temperature
Minimum airflow
output
No fuel detection
time
Ex.temp.w.no
fuel
Reserve boiler
*
Alarms
Boiler cooling te
m
perature
Parameter A
FL
Parameter B FL
Parameter C FL
Firing-
up
Firing-up airflow
Ignition test ti
me
Ignition test ti
me 2
Feeding time
Firing-up time
Ex.temp.delta
Ex.temp.delta 2
Ex.temp.at the
end of fired-
up
Test dose
Output modulation
100% Blow
-in output
100% Feeder oper
ation
100% Feeder in
terval
50% Blow-
in output
50% Feeder opera
tion
50% Feeder inter
wal
30% Blow-
in output
30% Feeder opera
tion
30% Feeder inter
val
Burning off
Buring off time
Air flush intensi
ty
Supervision
Supervision ti
me
Feed time
Feed interval
Airflow oper.ex
tend
Lambda sensor
*
Operation w
it
h Lambda sensor
Parameter A La
m
bda
Parameter B La
m
bda
Parameter C La
m
bda
Airflow correction
range
Feed lock
Fuel detection
- oxygen
Fuel detection
- time
CH and HU
W
settings
CH pump activation
t
emp.
CH pump stands
till when
load. HUW
Min. HUW temp.
Max. HU
W
temp.
Boiler inc. by HU
W, Mixer
Extending H
UW pump operation
time
Exchange
r
Boiler pump lock
Mixer 1-4
settings
*
Mixer suppo
rt
Thermostat sele
c
tion
Min. mixer te
m
p.
Max. mix
er temp.
Proportional rang
e
Integr. time cons
t
.
Valve opening ti
m
e
Pump off by ther
m.
Mixer inpu
t dead zone
*- menu for all mixer cycles is identical
20
22
Table of Contents
Default Chapter
4
Table of Contents
4
1 Recommendations Regarding
6
Safety
6
2 General Information
7
3 Information Documentation
7
4 Storage of Documentation
7
5 Applied Symbols
7
6 Directive Weee 2002/96/Eg
7
7 Structure - Main Menu
9
8 Operating the Regulator
10
Description of Display Main Window
10
Switching on and off the Boiler
10
Setting Preset Boiler Temperature
11
Firing-Up
11
Operation Mode
11
Operation in I.fuzzyl
12
Ogic Mode
12
Operation in the Standard Mode
13
Supervision Mode
13
Burning off
14
Standstill
14
Domestic How Water Settings
14
Setting Preset Dhw
14
Dhw Tank Hysteresis
14
Enabling the Summer
14
Dhw
14
Temperature
14
Function
14
Dhw Tank Disinfection
15
Mixer Circuits Settings
15
Weather Controlled Operation
16
Description of Settings for Night
17
Circulating Pump Control
18
Fuel Level Setup
18
Operation with Additional Feeder
18
Information
19
Manual Control
19
Operation in Accordance with the Schedule
19
Favourite Menu
19
9 Service - Menu Structure
21
10 Hydraulic Diagrams
22
Schema 1
22
Schema 2
23
11 Technical Data
24
12 Conditions of
24
Transport
24
13 Mounting Requirements
24
Environmental Conditions
24
Installation Requirements
24
Assembly of Control Panel
24
Mounting of Working Module
25
Disassembly of Control Panel
26
Ip Rating
26
Electric Connection
26
Protective Connection
27
Connection of Temperature Sensors
30
Connection of Weather Sensor
30
Testing of Temperature Sensors
30
Connection of Mixers Room Thermostat
31
Connection of Reserve Boiler
31
Connection of Alarm Announcing
32
Connection of Mixer
33
Connection of Circulating Pump
33
Connection of Stb
34
Connection of Room Control Panel
34
Temperature Limiter
34
14 Boiler Service Settings
35
Firing-Up
35
Burining-Off
35
Supervision Time
35
Feed . Time
35
Feeder Intercal
35
Airflow Oper
35
Superv
35
Supervision Mode
35
Thermostat Selection
36
Min. Preset Boiler Temperature
36
Max. Pre-Set Boiler Temperature
36
Min. Blow-In Output
36
No Fuel Detection Time
36
Maximum Feeder Temperature
36
Poker Cycle Time
36
Reserve Boiler
37
Boiler Cooling Temp
37
A, B, Cparameters of
37
15 And Cuw Service Settings
37
Pump Activation Temperature
37
Pump Standstill at Huw
37
Min Huw Temperature
37
Max Huw Temperature
37
Ndividual Fuzzy Logic
37
Loading
37
Increase of Boiler Temperature by
38
Circuit and Buffer Status
38
Huw Operations Ext
38
Heat Exchanger
38
16 Mixer Service Settings
38
Mixer Support
38
Thermostat Selection
39
Min. Preset Mixer Temperature
39
Max. Preset Mixer Temperature
39
Proportional Range
39
Integr. Time Const
39
Valve Opening Time
39
Pump off by Thermostat
39
17 Show Advanced Setup
39
18 Service Counters
39
19 Restore Factory Settings
40
20 Fan Rotation Detection
40
21 Lambda Sensor
40
22 Alarm Description
40
Xcess of Max Boiler Temperature
41
Xcess of Max Feeder Temperature
41
Boiler Temperature Sensor Damage
41
Feeder Temperature Sensor Damage
41
No Communication
42
Unsuccessful Boiler Firing-Up Attempt
42
Unsuccessful Attempt of Container Loading
42
Fan Damage
42
23 Others
42
Power Failture
42
Anti-Freezing Protection
42
Protection of Pumps against Clogging
42
24 Replacement of Parts and
42
Components
42
Replacement of Control Panel
43
Replacement of Working Module
43
Software Up-Grade
43
25 Troubleshooting
44
26 Regulator Setup by Boiler Manufacturer
45
Activating Individual Fuzzy Logic and Changing Boiler Type
45
4
Based on 1 rating
Ask a question
Give review
Questions and Answers:
Need help?
Do you have a question about the Plum ecoMAX810P3-L TOUCH and is the answer not in the manual?
Ask a question
Plum ecoMAX810P3-L TOUCH Specifications
General
Brand
Plum
Model
ecoMAX810P3-L TOUCH
Category
Controller
Language
English
Related product manuals
Plum ecoMAX920P1-K TOUCH
48 pages
Plum ecoMAX920P1-K
48 pages