CelloTrack LTE Plus Overview
CelloTrack XT LTE Overview.docx Page 34 of 40
Copyright © 2020 by Pointer Telocation, Ltd.
6 CelloTrack Power Features
CelloTrack Power includes a built-in CCCV battery charger (not included in the
standard CelloTrack unit).
The charger charges the unit’s back-up battery whenever an external energy source is
available and the temperature is within the charging range.
The CelloTrack Power unit also does the following:
Indicates the charger status in its update messages.
Continually reports the unit’s temperature.
Enables increased time and distance event frequency while powered by an external
power source.
The CelloTrack Power activates the charger when all the following conditions are met:
The temperature is between -20°C and 60°C (note that during charging, the unit
generates heat that might increase the temperature by 5-6°C).
An external power source is detected.
The unit is running in the Tracking state (this is the default setting; it is also
possible to enable charging in the Hibernation state).
The unit terminates charging when any of the following conditions are met:
The temperature is out of the permitted range.
The external power source is disconnected.
The unit enters the Hibernation state (if charging in Hibernation is disabled).