FR | 7
EN
2.3 Technical specifications
2. DESCRIPTION
MAG3 MAG4 MAG5
Air
(1)
26°C
Water
(2)
26°C
Heating power (kW)
3,05 4 5
Consumption (kW)
5.48 7.27 8.96
COP (Coe. of performance)
5.55 5.5 5.58
Air
(1)
15°C
Water
(2)
26°C
Heating power (kW)
2.26 3 3.8
Consumption (kW)
2.5 3.26 4.2
COP (Coe. of performance)
4.2 4.1 4.3
Air
(1)
35°C
Water
(2)
27°C
Cooling capacity (kW)
1.9 2.5 3.2
Consumption (kW)
0.613 0.833 1.032
EER (Energy Eciency Ratio)
3.1 3 3.1
Electricity supply
Single-phase 220-240V ~ 50Hz
Maximum power (kW)
0.95 1.2 1.2
Maximum current (A)
4.3 5.6 6.9
Heating temperature range
15°C ~ 40°C
Operating range
-5°C ~ 43°C
Unit dimensions L × W × H (mm)
420x290x430 420x290x430 470x290x430
Unit weight (kg)
25 26 28
Sound pressure level at 10 m (dBA)
(3)
<35 <35 <36
Hydraulic connection (mm)
PVC 32 / 38mm
Heat exchanger
PVC tank and Titanium coil
Min. water ow rate (m³/h)
2 2 2.5
Compressor type
Rotary
Refrigerant
R32
Waterproof IP
IPX4
Load loss (mCE)
0.8 0.8 0.9
Max. pool volume (m
3
)
(4)
Control panel
LED control screen
Mode
Heating / Cooling
The technical specications of our heat pumps are provided for information purposes only. We reserve the right
to make changes without prior notice.
1
Ambient air temperature
2
Initial water temperature
3
Noise at 10 m in accordance with Directives EN ISO 3741 and EN ISO 354
4
Calculated for an in-ground private swimming pool covered with a bubble cover.