22 | FR
4. USE
The system’s settings can be checked and adjusted via the remote control by following
these steps. Caution, some settings cannot be modied, check the settings table for more information.
Step 1: Switch o󰀨 the heat pump.
Step 2: Keep pressing for 3 seconds to access the settings.
Step 3: Select the desired setting using the down and up arrows
Step 4: Press on to select the setting to be adjusted.
Step 5: Press on to save the new value.
WARNING: This operation is used to assist servicing and future repairs.
The default settings should only be modied by an experienced professional person.
4.11 Advanced settings
Parameters Indication Adjustment range
Default
V.
Comments
C0 Setting inlet water temp in heating mode 15°C~40°C 38°C adjustable
C1 Water temp di󰀨erence for restart in heating mode 1°C~10°C 3°C adjustable
C2 Auto restart(0-without, 1-with) 0~1 1 adjustable
C3 Protection setting for too high discharge temp 30°C~120°C 110°C adjustable
C4 Max. inlet water setting temp in heating mode 30°C~60°C 40°C adjustable
C5 Min. inlet water setting temp in heating mode 5°C~30°C 15°C adjustable
C6 Di󰀨erence water temp to stop in heating mode 0°C~18°C 0 adjustable
C7 Setting inlet water temp in cooling mode 7°C~30°C 26°C adjustable
C8 Water temp di󰀨erence for restart in heating mode 0°C~18°C 3°C adjustable
C9 Di󰀨erence water temp to stop in cooling mode 0°C~18°C 0 adjustable
C10 Max. inlet water setting temp in cooling mode 20°C~35°C 30°C adjustable
C11 Min. inlet water setting temp in cooling mode 3°C~18°C 7°C adjustable
C12 Protection setting for too low ambient temp -25-20°C -7°C* adjustable
C13 Protection setting for too high ambient temp when heating 35-60°C 42°C adjustable
C14 Protection temp di󰀨erence for ambient temp 1-10°C 1°C adjustable
C26 AUX turn On ambient temp in heater Auto mode 0°C ~ 20°C 15 adjustable
C27 AUX water temp di󰀨erence for restart in heater Auto mode 1~5°C 5 adjustable
C28 AUX water temp di󰀨erence for restart in Manual mode 1~5°C 2 adjustable
C29 Setting inlet water temp in Auto mode 7°C~40°C 38°C adjustable
C30 PUMP parameter 0 (deactivated)
/1 (activated)
0 adjustable
C31 PUMP working interval of time 30-90 min 60 min adjustable
C32 AUX parameter 0 (deactivated)
/1 (activated)
1 adjustable
C33 Protection setting for too high ambient temp when cooling 25-60°C 35°C adjustable
C34 Manual defrosting
0 (deactivated)
/1 (activated)
0 adjustable
H0 Defrosting mode activation timer 1~240min 45 min adjustable
H1 Defrosting mode max. duration 1~25min 8 min adjustable
H2 Defrosting exit coil temp 1~25°C 12°C adjustable
H3 Defrosting entry coil temp -20~20°C -1°C adjustable
H4 Temp di󰀨erence between defrosting entry ambient temp
and coil temp
0~15°C 5°C adjustable
H5 Min. Ambient temp to entry defrosting 0~20°C 20°C adjustable
P1 CN6 function selection 0 : no function
1 : high pressure
switch (reserved)
2 : water ow switch
(reserved)
3 : in.grip function
3
When OFF, pressing on for 5 seconds resets the settings to factory settings.

Table of Contents