20
Useful information about how the heating mode operates
When the incoming water temperature is less than or equal to the required temperature (setpoint temper-
ature) -X°C, the heat pump will switch to heating mode. The compressor will stop when the temperature of
the incoming water is greater than or equal to the required temperature (setpoint temperature) +Y°C.
Indicators for adjustment range X and Y
X : adjustable parameter from 2° to 10°C, default setting is 3°C
Y : adjustable parameter from 0° to 6°C, default setting is 0°C
Step 1: Press to switch on your pump.
Step 2: Press to switch from one mode to another until the heating mode is displayed. Step 3:
Using buttons and select the required temperature (15-40°C).
EXAMPLE:
If you have selected 28°C, your screen will display:
Once the symbol stops
blinking, the required temperature
is validated and is replaced by the
water’s current temperature (25°
in our example).
4. Use
4.3 Heating Mode
Required
temperature“Blinking”
Current water
temperature
Current temperature
of the ambient air
WARNING: Before starting, ensure that the ltration pump is operating correctly.