25
Parameters table
4. Use 4. Use
* Setting 2 is for modifying the interval of degrees lost in relation to the required temperature, for the heat pump to restart.
Example: If the value of setting 2 is 3°C, after reaching the required temperature
(e.g. e.g. 27°C), the heat pump will restart when the pool temperature goes down to 24°C (27 - 3).
** Setting 3 is for modifying the degree of accuracy for heat pump shutdown.
Example: By conguring the compressor shutdown at 2°C and the required temperature at 27°C, the heat pump will cease working
when it reaches a pool temperature of 29°C (27+2).
Description Adjustment range
Factory
setting
Remarks
0 Automatic restart
0 = Off
1 = On
1 Adjustable
1 START/STOP times programming
0 = start only
1 = daily
1 Adjustable
2* Adjustment of temperature difference for restart Adjustable from 2 to 10°C 3°C Adjustable
3** Adjustment of compressor shutdown margin Adjustable from 0 to 3°C 0°C Adjustable
4 Auto-activation time before de-icing commences Adjustable from 30 to 90 mins 40 mins Adjustable
5 De-icing activation temperature Adjustable from 0 to -30°C 0°C Adjustable
6 De-icing deactivation temperature Adjustable from 2 to 30°C 2°C Adjustable
7 Maximum de-icing duration Adjustable from 0 to 15 mins 10 mins Adjustable
8 Compressor thermal protection
Adjustable from 95 to 120°C
Displayed values
9596979899A0A1
A2A3A4A5A6A7A8
A9b0b1b2b3b4b5
b6b7b8b9C0
118°C
Displayed
value b8
Adjustable
9 Maximum temperature 40~65°C 40°C Adjustable
10 Filtration pump servo-control mode
0 = Normal
1 = Special
1
Adjustable
(see Section 5.2)
11
Pump stopping time when temperature reached
(if setting 10 = 1)
Adjustable from 3 to 20 mins 15 mins Adjustable
12 Reserved - Do not modify 0 / 1 1 Adjustable
13 Reserved - Do not modify 0 / 1 / 2 2 Adjustable
14 Water intake temperature -9~99°C Actual data
15 Water outlet temperature -9~99°C Actual data
16 Coil temperature -9~99°C Actual data
17 Air outlet temperature -9~99°C Actual data
18 Ambient air temperature -9~99°C Actual data