Describes the system's behavior during normal operation, including indicators and detected parameters.
Explains the system's response to a loss of ground condition and its detection.
Details how the system detects and responds to a ground fault condition.
Covers the detection and indication of high third harmonic levels.
Provides a summary of system events and their corresponding field conditions.
Guidance on receiving the grounding unit and performing preliminary inspection.
Instructions for safely moving and lifting the free-standing units.
Precautions for storing the unit to maintain its condition.
Requirements for foundation strength, levelness, and conduit clearance.
Critical safety instructions for properly grounding the unit before power connection.
Details on connecting power lines and control wiring to the unit.
Method for adjusting resistor taps to match system capacitive-charging current.
Final checks for cleanliness and removal of shipping restraints.
Steps to energize the grounding system and connect it to the power source.
Process for inputting necessary setup data into the operator's panel.
Procedure to test the ground fault detection and alarm functionality.
Explanation of zero-sequence charging current and its determination.
Detailed steps for measuring the system's capacitive-charging current.
Guidance on interpreting test results and setting fault current limits.
Describes the messages displayed during system power-up and self-test.
Lists parameters that can be configured from the front panel.
How to enter and navigate the controller's configuration mode.
Settings to enable or disable voltage and amperage measurement displays.
Configuration of the Current Transformer (CT) ratio for measurements.
Setting high limits for voltage and amperage to trigger alarms.
Setting low limits for voltage and amperage to detect conditions.
Setting the duration for the pulsing feature used for fault location.
Setting the delay time before alarms are activated after a fault.
Configuration of the auto-reset feature for fault clearing.
Steps for activating the pulsing feature to trace and locate ground faults.
Recommended steps for performing periodic inspections to ensure system functionality.
| Category | Industrial Electrical |
|---|---|
| Display | LCD with backlight |
| Frequency | 50/60 Hz |
| Alarm Relays | 2 Form C relays |
| Communication | Modbus RTU |
| Protection | Short circuit |