2.4 Operation
1. Do not disconnect the mains cable on the Solar Inverter system or the
building wiring socket outlet during operations since this would cancel the
protective earthing of the Solar Inverter system and of all connected loads.
2. The Solar Inverter has its own internal power source (batteries). The output
terminals may be live even when the Solar Inverter is not connected to the
AC supply.
3. Ensure that no fluids or other foreign objects can enter the Solar Inverter
system.
2.5 Maintenance and Service
1. Caution - risk of electric shock.
Even after the unit is disconnected from the mains power supply (building
wiring socket outlet), components inside the Solar Inverter system are still
connected to the battery and are still electrically live and dangerous. Before
carrying out any kind of servicing and/or maintenance, disconnect the
batteries and verify that no current is present.
2. Batteries may cause electric shock and have a high short-circuit current.
Please take the precautionary measures specified below and any other
measures necessary when working with batteries:
- remove wristwatches, rings and other metal objects
- use only tools with insulated grips and handles.
5
3. CABLE CONNECTION
3.1 Inspection
1. The system may be installed and wired only by qualified electricians in
accordance with applicable safety regulations.
2. When installing the electrical wiring, please note the nominal amperage of
your incoming feeder.
3. Inspect the packaging carton and its contents for damage. Please inform
the transport agency immediately should you find signs of damage.
Please keep the packaging in a safe place for future use.
4. Please ensure that the incoming feeder is isolated and secured to prevent
it from being switched back on again.
3.2 Connection
1. Solar Inverter Input Connection
If the Solar Inverter is connected via the power cord, please use a proper
socket with protection against electric current, and pay attention to the
capacity of the socket.
2. Solar Inverter Output Connection
The output of this model is with socket-types only (NEMA or IEC). Simply
plug the load power cord to the output sockets to complete connection.