27
OPERATION:
• Load Mode Setting
Operating Steps:
Under load mode setting interface, press SET button and hold on 5s till the
number begin flashing, then press MENU button to set the parameter, press
SET button to confirm.
1** Timer 1 2** Timer 2
100 Light ON/OFF 2 n Disabled
101
Load will be on for 1 hour
since sunset
201
Load will be on for 1 hour
before sunrise
102
Load will be on for 2 hours
since sunset
202
Load will be on for 2 hours
before sunrise
103~113
Load will be on for 3~13
hours since sunset
203~213
Load will be on for 3~13
hours before sunrise
114
Load will be on for 14 hours
since sunset
214
Load will be on for 14 hours
before sunrise
115
Load will be on for 15 hours
since sunset
215
Load will be on for 15 hours
before sunrise
116 Test mode 2 n Disabled
117
Manual mode
(Default load ON)
2 n Disabled
CAUTION
When selecting the load mode as the Light ON/OFF mode, Test
mode, and Manual mode, only the Timer 1 can be set; and the
Timer 2 is disabled and display "2 n".