PQR
Series Model D52
Page 27
www.Powertronics.com
V2.1
In the event that you would like to communicate with the PQR D52 without using the PQR Host
Communications software, you can connect using most other terminal emulator software.
Commands:
The PQR D52 will respond to commands received through the serial port. All commands are
started with a C. Entering C, followed by the command number will initiate the function.
The commands are as follows:
C0 Transmit the Command Menu
C1 Transmit the Unit Version number
C2 Transmit a Summary Report
C3 Transmit a Detail Report
C4 Transmit a Data Log of recorded voltage
C5 Clear all events, and data log
C6 Set the Date and Time
C90 Continuous transmission of channels readings
CX Hang up the phone .
After the PQR D52 has completed the task initiated by the operator command, it returns on-line
to it’s monitoring duties. Each of the commands are detailed in the following pages.
Other Communications