3.4 Battery Parameter Settings
The following are configurable settings for battery-related parameters.
When there is a difference between the battery voltage monitored
by the controller and the value measured by a multimeter, the
battery voltage can be calibrated using this setting.
Long-press the BAT/▲ key to enter the setting program. Adjust
the numerical value using the BAT/▲ and BAT/▼ keys, then press the PV/SET key to save and
confirm.
In parallel operation mode, each controller must have a defined communication code. If not
operating in parallel, there is no need to configure this program.
The host is determined by the controller with the smallest communication code. During parallel
operation, if the host encounters an issue, the system will automatically designate the controller
with the next code as the new host. For instance, if the host with code 01 experiences a
malfunction, the system will redefine controller 02 as the new host.
Assuming six controllers are operating in parallel, and the communication codes for the six devices
are sequentially defined as one of the numbers from 01 to 06 (with each device having a unique
communication code, and no repetition of communication codes among the devices).