Foreword
Thank you for choosing Powtran PI500-S Series Solar inverter. This
product made by Powtran is based on years of experience in professional
production and sale, and designed for variety of industrial machinery, fan and
water pump drive unit and IF heavy-duty grinding unit.
This manual provides user the relevant precautions on installation,
operational parameter setting, abnormal diagnosis, routine maintenance and
safe use. In order to ensure correct installation and operation of the frequency
converter, please carefully read this manual before installing it.
For any problem when using this product, please contact your local dealer
authorized by this company or directly contact this company, our professionals
are happy to serve you.
The end-users should hold this manual, and keep it well for future
maintenance & care, and other application occasions. For any problem within
the warranty period, please fill out the warranty card and fax it to the our
authorized dealer.
The contents of this manual are subject to change without prior notice. To
obtain the latest information, please visit our website.
For more product information, please visit: http:// www.powtran.com.
Powtran
January, 2018

Table of Contents

Questions and Answers

  • T
    timothy18Nov 21, 2025
    What to do if my Powtran Inverter displays Err.02?
    • C
      Christopher HarrisNov 21, 2025
      If the Powtran Inverter shows Err.02, it could be due to several reasons: * The acceleration time might be too short, in which case you should increase it. * The manual torque boost or V/F curve might be unsuitable, so adjust them. * Low voltage can cause this, so set the voltage to the normal range. * A short-circuit or earthing of the inverter output requires you to eliminate peripheral faults. * If using vector control mode without parameter identification, perform identification for the motor parameters. * If the motor starts unexpectedly while rotating, select Speed Tracking Start or restart after stopping the motor. * A sudden increase in load during acceleration may trigger this, so cancel the sudden load. * If the inverter type is too small, choose one with a large...
  • T
    Tracy BartlettAug 25, 2025
    What causes Err.03 on a Powtran PI500-S 022G3 and how to fix it?
    • A
      Ashley WellsAug 26, 2025
      The Err.03 error on your Powtran Inverter can arise from several factors. Here's what to check: * A short-circuit or earthing of the inverter output. If this is the case, eliminate peripheral faults. * If you're using vector control without identifying parameters, perform motor parameter identification. * A deceleration time that's too short. Increase the deceleration time. * Low voltage can cause this error. Set the voltage to the normal range. * If the load suddenly increases during deceleration, cancel the sudden load. * Lack of a braking unit and braking resistor. Install a braking unit and brake resistor.
  • Z
    Zachary WongAug 27, 2025
    Why does my Powtran PI500-S 022G3 show Err.04?
    • J
      John JeffersonAug 27, 2025
      The Err.04 error on a Powtran Inverter can be attributed to the following reasons: * A short-circuit or earthing of the inverter output. If this occurs, eliminate peripheral faults. * If the control mode is vector and parameters haven't been identified, perform identification for the motor parameters. * Low voltage can trigger this error; set the voltage to the normal range. * A sudden increase in load during operation may also cause it; cancel the sudden load. * If the inverter type is too small, select an inverter with a larger power level.
  • C
    Caroline OchoaAug 27, 2025
    What does Err.05 mean on my Powtran Inverter?
    • K
      Katelyn PerezAug 27, 2025
      If your Powtran Inverter displays Err.05, consider the following potential causes and solutions: * If a braking unit and braking resistor haven't been installed, install them. * High input voltage can cause this error. Set the voltage to the normal range. * External force dragging the motor during acceleration can trigger this. Cancel the external force or install a braking resistor. * If the acceleration time is too short, increase it.
  • J
    joseph95Aug 29, 2025
    How do I fix Err.06 on my Powtran PI500-S 022G3?
    • T
      troyobrienAug 29, 2025
      If you're seeing Err.06 on your Powtran Inverter, here's what you should check: * High input voltage. Set the voltage to the normal range. * External force dragging the motor during deceleration. Cancel the external force or install a braking resistor. * A deceleration time that's too short. Increase the deceleration time. * Missing braking unit and braking resistor. Install a braking unit and brake resistor.
  • C
    Christina RiveraSep 18, 2025
    What does Err.22 mean on Powtran Inverter?
    • A
      Andre FisherSep 18, 2025
      If your Powtran Inverter displays Err.22, it means there is an overvoltage or overcurrent. Eliminate the overvoltage or overcurrent fault.
  • B
    barrettmckenzieSep 15, 2025
    What does Err.15 on Powtran PI500-S 022G3 Inverter mean?
    • R
      Rebecca BonillaSep 15, 2025
      If your Powtran Inverter is displaying Err.15, it means an external fault signal was input through the multi-function terminal DI. Reset run.
  • D
    Debbie RodriguezSep 17, 2025
    What does Err.21 mean on Powtran PI500-S 022G3 Inverter?
    • E
      Elizabeth ByrdSep 18, 2025
      If your Powtran Inverter displays Err.21, it indicates that the EEPROM chip is damaged. Replace the main control panel.
  • T
    Tina ScottSep 7, 2025
    What to do if Powtran Inverter shows Err.12?
    • T
      Terry Johnson Jr.Sep 7, 2025
      If your Powtran Inverter displays Err.12, it could be due to: * An abnormal drive panel. Replace the drive, the power board or contactor. * An abnormal lightning protection plate. Seek technical support. * An abnormal main control panel. Check and eliminate the existing problems in the peripheral line.
  • M
    Matthew GonzalezSep 5, 2025
    What does it mean when my Powtran PI500-S 022G3 shows Err.11?
    • C
      christophermossSep 5, 2025
      If your Powtran Inverter is displaying Err.11, consider these possibilities: * The power grid voltage might be too low. Check the power grid voltage. * The motor protection parameters (F8.03) might not be set appropriately. Correctly set this parameter. * The load could be too large, or the motor might be stalling. Reduce the load and check the motor and its mechanical condition.

Summary

Chapter 1 Inspection and Safety Precautions

1-2 Safety Precautions

Detailed safety warnings categorized by process (before installation, during installation, wiring, before energizing, during operation, maintenance).

Chapter 2 Standard Specifications

2-1 Technical Specifications

Technical details including power, current, and adaptive motor ratings for various inverter models.

Chapter 3 Keyboard Interface and Operation

3-2 Parameter Setting Procedures

Guides for viewing/modifying parameters, reading status, password settings, and motor auto-tuning.

Chapter 4 Installation and Commissioning

4-1 Environment and Installation

Details on suitable operating environment, installation direction, and required space.

4-2 Wiring Diagrams and Precautions

Wiring descriptions for main and control circuits, along with essential wiring safety precautions.

Chapter 5 Function Parameter Reference

Chapter 6 Troubleshooting

6-1 Fault Alarms and Countermeasures

Lists common fault codes, their possible causes, and recommended solutions for quick resolution.

Chapter 8 Maintenance and Repair

Appendix II Communication Protocol Details

Powtran PI500-S 022G3 Specifications

General IconGeneral
BrandPowtran
ModelPI500-S 022G3
CategoryInverter