I
Foreword
Thank you for choosing POWTRAN PI130 Series Frequency Inverter. This
product made by POWTRAN is based on years of experience in professional production
and sale, and designed for variety of industrial machinery, fan and water pump drive
unit and IF heavy-duty grinding unit.
This manual provides user the relevant precautions on installation,operational
parameter setting, abnormal diagnosis, routine maintenance and safe use. In order to
ensure correct installation and operation of the frequency converter, please carefully
read this manual before installing it.
For any problem when using this product, please contact your local dealer
authorized by this company or directly contact this company, our professionals are
happy to serve you.
The end-users should hold this manual,and keep it well for future maintenance &
care,and other application occasions. For any problem within the warranty period,please
fill out the warranty card and fax it to the our authorized dealer.
The contents of this manual are subject to change without prior notice. To obtain
the latest information, please visit our website.
For more product information, please visit: http://www.powtran.com.
POWTRAN
July,2013

Table of Contents

Questions and Answers

  • B
    Brett WallAug 20, 2025
    Why is my Powtran pi130 Inverter showing overcurrent when accelerating?
    • T
      tonyjonesAug 20, 2025
      If your Powtran Inverter shows an overcurrent error during acceleration, it could be due to several reasons. The acceleration time may be too short, so try increasing it. Also, check the input power, as low mains voltage can cause this issue. If the inverter's power is insufficient for the load, consider choosing an inverter with larger power. Finally, inspect the output wiring for any phase loss.
  • J
    Jose Smith MDAug 22, 2025
    What to do if Powtran pi130 shows overcurrent at constant speed?
    • L
      Lauren JordanAug 22, 2025
      If you're experiencing overcurrent with your Powtran Inverter while running at a constant speed, it could be due to a load issue. Check for any load mutations or abnormalities and try reducing the load if possible. Low mains voltage can also cause this, so check the input power. If your inverter's power is too small for the application, consider using a larger one. Also, check the output wiring for phase loss.
  • P
    philip42Aug 25, 2025
    Why is my Powtran pi130 showing overvoltage when decelerating?
    • A
      austinmccallAug 25, 2025
      If your Powtran Inverter is showing an overvoltage error during deceleration, it might be because the deceleration time is too short; try increasing it. A large load inertia could also be the cause, so consider increasing braking components of energy consumption. Additionally, check the input power, as abnormal input voltage can lead to overvoltage.
  • M
    Mrs. Krystal LaneAug 26, 2025
    What causes overcurrent when decelerating Powtran pi130 Inverter?
    • M
      Miguel WongAug 27, 2025
      If your Powtran Inverter displays an overcurrent error during deceleration, it could be because the deceleration time is too short, so try increasing it. Another reason might be a large load inertia, in which case you should add suitable braking components. If the inverter's power is too small, choose one with larger power. Also, check the output wiring for phase loss.
  • R
    Robin CookAug 27, 2025
    Why is my Powtran Inverter overloading?
    • N
      Nancy StaffordAug 28, 2025
      If your Powtran Inverter is showing an overload error, there are several potential causes. It could be due to accelerating too quickly, so try increasing the acceleration time. Avoid restarting the motor while it's still rotating. Check the mains voltage, as low voltage can cause an overload. Finally, the inverter itself might be undersized for the load, so consider choosing an inverter with larger power.
  • J
    jacquelinesmithAug 29, 2025
    What causes overvoltage when accelerating Powtran Inverter?
    • L
      Lisa HarrisAug 29, 2025
      If your Powtran Inverter is showing an overvoltage error during acceleration, it may be due to abnormal input voltage, so check the input power. Avoid restarting the motor after a momentary power failure while it is still rotating. If the acceleration time is too short, try increasing it.
  • R
    Ronald Dickerson IIAug 31, 2025
    How to fix motor overload on Powtran pi130 Inverter?
    • L
      Lisa SmithAug 31, 2025
      If you're experiencing a motor overload with your Powtran Inverter, it could be due to several reasons. The mains voltage might be too low, so check it. The motor's rated current might be set incorrectly, so reset it. A motor stall or excessively large mutation load can also cause this; check the load and adjust torque boost. Finally, the motor itself might be inadequate; select an appropriate motor.
  • J
    Jamie MedinaSep 2, 2025
    What to do if Powtran pi130 Inverter displays bus undervoltage shutdown?
    • S
      Susan MoyerSep 2, 2025
      If your Powtran Inverter is displaying a bus undervoltage shutdown, it could be due to low mains voltage, so check the mains input power. It's also possible that the parameters are set incorrectly, so verify their accuracy.
  • T
    Thomas PerezSep 4, 2025
    Why Powtran pi130 shows overvoltage at constant speed?
    • M
      Marisa MooreSep 4, 2025
      If your Powtran Inverter shows overvoltage at constant speed, it could be due to abnormal changes in input voltage; consider installing an input reactor. Also, large load inertia can cause this; add suitable braking components.
  • L
    lparkSep 6, 2025
    How to prevent Powtran Inverter module from overheating?
    • D
      david63Sep 6, 2025
      If your Powtran Inverter module is overheating, there are several potential causes. It could be due to an instantaneous overcurrent, so refer to the solutions for overcurrent. Check the output three-phase wiring for interphase shorts or shorts to ground, and re-wire if necessary. Ensure the air duct isn't blocked or damaged; clean or replace it. High ambient temperature can also cause overheating, so decrease the ambient temperature. Check and reconnect any loose wires or plug-ins on the dashboard. If the auxiliary power supply is damaged or the inverter is undervoltage, or if there's a straight through of the power module bridge, seek for service. Also, seek for service, if the control panel is damaged.

Summary

Product Foreword

Inspection and Safety Precautions

Safety Precautions

Details dangers and cautions for installation, wiring, and operation.

Standard Specifications

Standard Specifications Details

Details control system, output frequency, V/F curve, and braking.

Keyboard Operation

Operation Panel Key Functions

Details the function of each key on the operation panel.

Parameter Settings Examples

Illustrates parameter viewing, modification, password settings, and auto-tuning.

Function Parameters

Motor Parameters Configuration

Parameters for configuring motor characteristics and auto-tuning.

Powtran pi130 series Specifications

General IconGeneral
BrandPowtran
Modelpi130 series
CategoryInverter
LanguageEnglish

Related product manuals