Note: please set up according to the motor nameplate parameters. The excellent
vector control performance needs the accurate motor parameters.
The inverter provides the function of parameter auto tunning. The accurate
parameter auto tunning depends on correctly inputing parameters on the motor
nameplate.
In order to guarantee the control performance, please try to ensure that the inverter
power matches the motor power, if the gap between the two is too large, the inverter
control performance will be significantly reduced.
Note: Resetting the motor rated power (b0.01) will initialize motor parameters
b0.06 to b0.10.
When the motor parameter auto tunning is competed, the set value of b0.06 to
b0.10 will be automatically updated. These parameters as the basis of high-
performance vector control have a direct impact on the control performance.