Chapter 5 Function parameter
39
No.
Code
Parameter name
Setting range
Factory
default
Change
Reference
page
138.
Fb.04
High-frequency
threshold point of
oscillation suppression
0 to 500
100
76
139.
Fb.05
Amplitude limit value
of oscillation
suppression
0 to 10000
5000
77
140.
Fb.06
Demarcation
frequency of high and
low frequency of
oscillation suppression
0.00Hz to F0.08
(maximum
output
frequency)
12.50Hz
77
141.
Fb.07
Oscillation
suppression
0: valid
1: invalid
1
77
142.
Fb.08
PWM selection
0: PWM mode 1
1: PWM mode 2
2: PWM mode 3
0
77
143.
Fb.09
Energy-saving
selection
0: OFF
1. Auto
0
77
144.
Fb.10
Deadband time
2 to 5
Depends
on models
77
5-1-14.E0 Group - Wobbulate control
No.
Code
Parameter name
Setting range
Factory
default
Change
Reference
page
145.
E0.00
Wobbulate range
0.0 to 100.0% (relative
to setting frequency)
0.0%
78
146.
E0.01
Sudden jump
frequency range
0.0 to 50.0% (relative
to Wobbulate
amplitude)
0.0%
78
147.
E0.02
Wobbulate rise
time
0.1 to 3600.0s
5.0 s
78
148.
E0.03
Wobbulate fall
time
0.1 to 3600.0s
5.0 s
78
5-1-15.E1 Group - Multi-speed control
No.
Code
Parameter name
Setting range
Factory default
Change
Reference page
149.
E1.00
Multi-speed 0
-100.0 to 100.0%
0.0%
78
150.
E1.01
Multi-speed 1
-100.0 to 100.0%
0.0%
78

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Powtran pi130 series and is the answer not in the manual?

Powtran pi130 series Specifications

General IconGeneral
BrandPowtran
Modelpi130 series
CategoryInverter
LanguageEnglish

Related product manuals