Section V. Function parameter table
Invalid 0
F42
OU stall protect
Valid 1
- 1 Y
Invalid 0
F43
current limit
Valid 1
- 0 Y
Invalid 0
Pick up mode when power
down
1
F44
rate track select
Pick up mode when start 2
- 0 N
Invalid 0
F45
elec. o.h. protect
Valid 1
- 1 Y
F46
protect level 120~250 %
★ N
Invalid 0
Safe mode 1
F47
consumed brake
General mode 2
- 0 Y
F48
Fault reset times
0~10 - 0 N
F49
Fault reset time 0.5~20.0 s 1.0 N
Single circulation 0
Continuous circulation 1
F50
Program running
mode
Single circulation command
running
2
- 0 N
Runs at step 1 0
F51
Restart mode
Runs at the step before
stopping
1
- 0 N
F52
*reserved - - - -
F53
*reserved - - - -
FWD command,motor
forwards
0
F54
Motor run direction
FWD command,motor
reverses
1
- 0 N
Reverse allowable 0
F55
Motor reverse
forbidden
Reverse forbidden 1
- 0 N
Acc/dec
time
Tens
digit
Run
time
Unit
*1 0 *1 0
*30 1 *10 1
F56
Running time setting
*100
2
- 0 N
Section V. Function parameter table
F57
% in energy saving
energy
30~100 %
100 N
F59~ F13 F03=0
0.00
F58
FDT fre. set 1
F59~ F13 F03=1
Hz
0.0
Y
0.00~ F58 F03=0
0.00
F59
FDT fre. set 2
0.0~ F58 F03=1
Hz
0.0
Y
0.00~5.00 F03=0
0.00
F60
Fre. Inspection
range
0.0~50.0 F03=1
Hz
0.0
Y
General 0
Water Pump 1
Blower fan 2
Plastic jetting mould machine
3
Braiding machine 4
Hoister 5
Pumping jack 6
Belt conveyor 7
F61
Load type
*reserved 8~14
0 N
Standard running control 0
2-point running control 1
F62
Terminal control
modes
3-point running control 2
- 0 N
Invalid 0
MSS multi-step speed control
1
MSS multi-step acceleration
control
2
JOG forward/ reverse control
3
Frequency set mode shift 4
*reserved 5
MSS time running 6
F63
MSS terminal
function selection
*reserved 7
- 0 N
F64
Polarity of input
terminal
0~127 - 0 N
Set frequency 0
Actual frequency 1
Actual motor current 2
F65
F66
Monitor sel. 1
Monitor sel. 2
Current percentage 3
-
-
1
2
Y
Y