INSTALLATION INSTRUCTIONS
Note: The equipment has a connector for interconnect it with
other equipment. This connector is intended to keep several
devices with the same electrical potential. Not necessarily the
grounding of a local connection. This connector on the back of
the device is identified by the symbol on the right:
Ÿ Use of pressure cables to prevent movement
of the power cable.
Ÿ In case the oven voltage is 380 volts, a
neutral cable (independent of the ground)
must be available.
Ÿ Ensure that the electrical characteristics of
the building power grid are in accordance
with the technical specifications located on
the data label located on rear panel of the
unit. The building power grid installation is
the customer's responsibility.
Ÿ This unit must be properly grounded to avoid
electrical shock .
Ÿ The circuit braker should be located no more
than 70,8in / 6ft / 1.8m away from the unit.
GENERAL INSTRUCTIONS
Ÿ The oven must be installed on a surface or counter that supports its
weight of approximately 147,7lb (67 Kg).
Ÿ Do not obstruct the air inlets and outlets at the front bottom of the oven.
Ÿ The oven must not be positioned near stoves, deep fryers, hot plates and
other equipment that releases fat, steam and heat. The ventilation,
electrical panel and motor vents must be far from these heat sources to
prevent damage to the electrical system of the equipment.
Ÿ The oven must be installed in a leveled and well-ventilated area.
Ÿ The installation of the equipment in a non-suitable place can result in the
loss of warranty.
6 